Optimised for water, oils and air. Red/green display for clear identification of the acceptable range. With switching output, analogue signal and IO-Link. The process connection can be rotated for optimum alignment.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications SA2000

Application
MediaWater, glycol solutions, backlash, oils
Medium note
low viscosity oils with viscosity: ? 40 mm?/s (40 °C)
high viscosity oils with viscosity:> 40 mm?/s (40 °C)
Measured medium temperature [°C]-20…90
Pressure strength [bar]100
MAWP (for CRN application) [bar] 85
Electronic data
Operating voltage [V]18…30 DC
Current consumption [mA]<100
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 2 , Number of analog outputs: 1
Outputs
Total number of outputs2
Output signalSwitching signal, analogue signal, frequency signal, IO-Link, (configurable)
Electric Hard versionPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed, (parameterizable)
Max. voltage drop of switching output DC [V]2.5
DC load current of switching output DC [mA]250
Number of analog outputs1
Analog current output [mA]4…20, (scalable)
Maximum load [?]350
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Output frequency [Hz]0…1000
Measuring/setting range
Probe length L [mm]19.2
Operating modeRelative, Absolute liquid, Absolute gaseous
Note on setting range
Operating mode: relative
Liquid media
Measuring range [m/s]0.04…3
Parameter setting within [m/s]0…6
Gases
Measuring range [m/s]2…100
Parameter setting within [m/s]0 …200
Temperature control
Measuring range [°C]-20 …90
Resolution [°C]0.2
Accuracy/Uncertainty
Flow rate control
Temperature drift [cm/s x 1/K]0.003 m/s x 1/K ( 70 °C)
Max. temperature gradient (rate of change of medium temperature) [K/min]100
Accuracy (in measuring range)± (7 % MW + 2 % MEW) instructions, Accuracy may differ for different media and mounting positions.)
Repeatability0.05 m/s, (Water, Flow velocity: 0, 05…3 m/s)
Temperature control
Temperature drift± 0.005 K/°C
Accuracy [K]± 0.3 / ± 1, (Water, Flow rate: 0.3…3 m /s / backlash, Flow velocity:> 10 m/s)
Response time
Flow velocity control
Response time [s]0.5, (T09, Water, glycol: 0.8 s, backlash: 7 s, oil: 1 .8 s, each T09)
Temperature control
Dynamics of response T05 / T09 [s]1.5 (T09), (Water, Flow rate: 0.3…3 m/s)
Software / Programming
Parameter selectionhysteresis/window, normally open/normally closed, switching logic, current/frequency output, medium selection, damping, learning function, display can be rotated and switched off, standard unit of measure, color of operating value
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO- Link verification1.1
SDCI standardIEC 61131-9
IO-Link device ID533 d / 00 02 15 h (REL)
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO Modeyes
Desired port typeA
Analog operating data2
Binary operating data yes data2
Min. cycle time [ms]3
Operating conditions
Ambient temperature [°C]-40…80
Storage temperature [°C]-40…100
Degree of protectionIP 65, IP 67
Tests / approvals
EMC
DIN EN 60947 -5-9
Impact resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g (10… 2000 Hz)
MTTF [years]143
UL Certification
UL Registration NumberI003
Mechanical data
Weight [g]323, 8
Materialstainless steel steel (1.4404 / 316L), stainless steel steel (1.4310 / 301), PBT-GF20, PBT-GF30 mediumstainless steel steel (1.4404 / 316L), gasket: FKM
Process connectionG 1/2 threaded connection
Displays / Controls
Display
Display 6 x LED, green (%, m/s, l/min, m?/h, °C, 10?)
Output status 2 x LED, yellow
Measured valuesalphanumeric display, red/green 4-digit
Notes
Notes
MW = Measured value
MEW = Upper limit of measuring range
540 d / 00 02 1ch (LIQU )
547 d / 00 02 23 h (GAS)
Packing quantity1 piece
Electrical connection
ConnectionConnector: 1 x M12, Contacts: gold-plated