Specifications SA4100

Application
MediaWater, glycol solutions, backlash, oils
Medium note
low viscosity oils with viscosity: ? 40 mm?/s (40 °C)
high viscosity oils with viscosity: > 40 mm?/s (40 °C)
Measured medium temperature [°C]-20…100
Pressure strength [bar]50
MAWP (for CRN application) [bar] 50
Electronic data
Operating voltage [V]18…30 DC
Current consumption [mA]< 100
Protection classIII
Reverse polarity protectionyes
Power-on delay time [s]10
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 2 , Number of analog outputs: 1
Outputs
Total number of outputs2
Output signalSwitching signal, analogue signal, frequency signal, IO-Link, (configurable)
Electric Hard versionPNP/NPN
Number of digital outputs2
Output functionnormally open / normally closed, (parameterizable)
Max. voltage drop of switching output DC [V]2.5
DC load current of switching output DC [mA]250
Number of analog outputs1
Analog current output [mA]4…20, (scalable)
Maximum load [?]350
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Output frequency [Hz]0…1000
Measuring/setting range
Probe length L [mm]100
Operating modeRelative, Absolute liquid, Absolute gaseous
Note on setting range
Operating mode: relative
Liquid media
Measuring range [m/s]0.04…3
Setting parameters within [m/s]0…6
Gases
Measuring range [m/s]2…100
Parameter setting within [m/s]0… 200
Temperature control
Measuring range [°C]-20… 100
Resolution [°C]0.2
Accuracy/Uncertainty
Flow rate control
Temperature drift [cm/s x 1/K]0.003 m /s x 1/K ( 70 °C)
Max. environment) [K/min]100
Accuracy (in measuring range)± (7% MW + 2% MEW), (for relative mode in the measuring range c:, Water: 20…70 °C, inlet pipe length: 1.5 m, DN25 (DIN 2448), installation position according to the instructions, Accuracy may differ for other media and mounting positions.)
Repeatability0.05 m/s, (Water, Flow velocity: 0.05…3 m/s)
Temperature control
Temperature drift± 0.005 K/°C
Accuracy [K]± 0.3 / ± 1, (Water, Flow velocity: 0.3…3 m/s / backlash, Flow velocity: > 10 m/s)
Reaction time
Flow rate control
Response time [s]0.5, (T09, Water, glycol: 0.8 s, backlash: 7 s, oil: 1.8 s, each T09)
Temperature control
Trip response time T05 / T09 [s]1.5 (T09), (Water, Flow rate: 0, 3…3 m/s)
Software / Programming
Parameter selectionHysteresis / window, normally open/normally closed, switching logic, current/frequency output, medium selection, damping, teach-in function, display can be rotated and switched off, standard unit of measure, process value color
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO-Link test1.1
SDCI standard IEC 61131-9
IO-Link device ID533 d / 00 02 15 h (REL)
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO Modeyes
Desired port typeA
Analog operating data2
Binary operating data2
Minimum operating cycle time [ms]3
Operating conditions
Ambient temperature [°C]-40…80
Storage temperature [°C]-40…100
Degree of protectionIP 65, IP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Impact resistance
DIN EN 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-65 g (10…2000 Hz)
MTTF [years]180
UL Certification
UL Registration NumberI003
Mechanical data
Weight [g]299.5
Materialstainless steel steel (1.4404 / 316L), PBT-GF20, PBT-GF30 mediumstainless steel steel (1.4404 / 316L)
Process connectionDiameter Ø 8 mm
Displays / Control elements
Display
Display6 x LED, green ( %, m/s, l/min, m?/h, °C, 10?)
Output status2 x LED, yellow
Measured valuesalphanumeric display, red/green 4-digit
Notes
Notes
MW = Measured value
MEW = Upper limit of measuring range
540 d / 00 02 1ch (LIQU)
547 d / 00 02 23 h (GAS)
Packaging size1 piece
electrical connection
ConnectionConnector : 1 x M12, Contacts: gold-plated