Application |
---|
Measuring element | Ceramic capacitive pressure cell |
Application | For general industrial applications |
Media | Liquid media |
< tr>Conditionally suitable | Use in gaseous media at pressures > 25 bar only on request | Measured medium temperature [°C] td> | -25…80 |
Pressure strength | 300 bar | 300 bar td> | 4350 psi | 30 MPa |
| Min. bursting pressure | 650 bar | 9400 psi | 65 MPa | < /tbody>
| Pressure Type | Relative Pressure | Electronic Data th> |
---|
Operating voltage [V] | 18…30 DC, (according to EN 50178 SELV/PELV) | Current consumption [mA] | < 35 | Min. insulation resistance [M?] | 100, (500 V DC) | Protection class | III | tr> Reverse polarity protection | yes | Power-on delay time [s] | 0.3 | Built-in watchdog | yes | Inputs/outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 | Outputs |
---|
< td>Total number of outputs2 | Output signal | switching signal, IO-Link, (configurable) | Electrical version | PNP/NPN | Number of digital outputs | 2 | Output function | normally open / normally closed, (parameterizable) | Max. voltage drop DC switching output [V] | 2.5 | DC switching output load current DC [mA] | 150, (200 (…60 °C) 250 (…40 °C)) | DC switching frequency [Hz] | < 170 | < /tr> Short-circuit protection | yes | Short-circuit protection type | clocked | td> | Overcurrent protection | yes | Measuring/setting range |
---|
Measuring range | 0…100 bar | 0…1450 psi | 0…10 MPa |
| Switching point SP | 1…100 bar | 10…1450 psi | 0.1…10 MPa | |
Reset point rP | 0.5…99.5 bar | 5…1445 psi | 0.05…9.95 MPa |
|
In steps of | |
Accuracy/Uncertainty |
---|
Switch Point Accuracy [% of Range] | < ± 0.5 |
Repeatability [% of range] | < ± 0.1, (for temperature changes < 10 K) | < /tr>
Specification Deviation [% of Range] | < ± 0.25 (BFSL) / < ± 0.5 (LS), (BFSL = Best Fit Straight Line, LS = Limit value setting) |
Hysteresis deviation [% of span] | < ± 0.25 |
Long-term stability [% of span] | < ± 0.05, (for 6 months) |
Zero point temperature coefficient [% of span / 10 K] | 0.2, (-25…80 °C) |
Temperature coefficient range [% of span / 10 K] | 0.2, (-25…80 °C)
Response time |
---|
Response time [ms ] | < 3 |
Programmable delay time dS, dr [s] | 0…50 |
Software / Software Control |
---|
Parameter selection | Hysteresis/window, normally open/normally closed, switching logic, on/off delay, damping, display |
Interfaces |
---|
Communication interface | IO-Link |
Transmission method | COM2 (38.4 kBaud) |
IO-Link test | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link device ID | 401 d / 00 01 91 h |
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis |
SIO mode | yes |
Desired port type | A |
Analog operating data | 1 |
Binary operating data | 2 |
Minimum operating cycle time [ms] | 2.3 |
Operating conditions |
---|
Ambient temperature [°C] | -25…80 |
Storage temperature [ °C] | -40…100 |
Degree of protection | IP 65, IP 67 |
Tests / approvals |
---|
EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-3 | |
|
Impact resistance | DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN EN 60068-2-6 | 20 g (10…2000 Hz) |
|
MTTF [years] | 236 |
UL certified | UL registration number | J002 |
|
Pressure Equipment Directive | Good engineering practice, can be used for fluid group 2, fluid group 1 on request |
Mechanical data |
---|
Weight [g] | 272 |
Material | stainless steel steel (1.4404 / 316L), PBT+PC-GF30, PBT-GF20, PC mediumstainless steel steel (1.4404 / 316L), ceramic, FKM |
Min. pressure cycles | 100 million |
Tightening torque [Nm] | 25…35, (recommended tightening torque, V depending on lubrication, sealing and pressure rating) |
Process connection | G 1/4 female thread |
< tr>Displays / Controls | Display | Display | 3 x LED, green (bar, psi, MPa) | Output status | 2 x LED, yellow | < tr>Measured values | alphanumeric display, red/green 4-digit |
|
< tr>Notes | Packing quantity | 1 piece |
Electrical connection th> |
---|
Connection | Connector: 1 x M12, Contacts: gold-plated |