Supply of spare parts for industrial enterprises around the world
Home Brands Pepperl+Fuchs 238626 VAN-115/230AC-K27

Pepperl+Fuchs VAN-115/230AC-K27 238626

Power supply VAN-115/230AC-K27 Pepperl+Fuchs 238626
Manufacturer
Pepperl+Fuchs
Name
VAN-115/230AC-K27
Part number
238626
Country
Germany
Type
Power supply
Weight (g)
744
Sale of any product from the Pepperl+Fuchs catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Pepperl+Fuchs (official website: www.pepperl-fuchs.com). We sell only certified goods and give an official guarantee from the manufacturer Pepperl+Fuchs


The primary switched-mode power supply was designed for fieldbus applications that transfer energy and data together via a two-wire cable (AS-Interface concept). It supplies a fully extended AS-Interface system with a maximum output current of 4.0 A. Due to the sinusoidal current consumption of the network, harmonics are avoided. The power supply assumes the function of supplying power, data decoupling for the power source and balancing both output lines (AS-Interface + and AS-Interface -) with respect to the machine ground (shielded connection). The transformer allows the use of unshielded load cables. The power supply is protected by an internal fuse that eliminates the need for additional device protection measures. Ground fault monitor GF: The switch output of the ground fault monitor evaluates any short circuits detected in the AS-Interface system. With the potential-free transistor output, the system can be shut down using the control program. The output is normally closed, but opens when a ground fault is detected. The GF LED also signals the presence of a ground fault. This output will close when the power supply is restarted or the reset button is pressed for (> 2 seconds). It is essential to connect the shield to PE or the machine ground to guarantee proper operation. Checking the ground fault monitor: Pressing the reset button briefly ( 2 seconds).
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications VAN-115/230AC-K27 238626

Product Description
AS-Interface power supply, data decoupling, 4 A
General specifications
UL File NumberE223176
MTBF100 a
Indicators/operating means
Reset push-button switchearth fault simulation/reset of earth fault display
LED EFDearth fault display, LED red
LED AS-i okLED green: ON: AS-Interface voltage OK OFF: overload or no supply voltage
Electrical specifications
FusingT3A 15/250 V HBC (not accessible)
Rated operating voltage85 &hellip, 132 VAC 184 &hellip, 264 VAC 240 &hellip, 300 VDC
Rated operating current2.7 A at 115 VAC 1.3 A at 230 VAC
Supply frequency47 ... 63 Hz (alternatively, DC possible)
Efficiencytyp. 90 % (230 VAC, 4 A)
Galvanic isolationSELV/PELV
Peak inrush current< 3.7 A2s (120 VAC) < 4.6 A2s (132 VAC) < 2.5 A2s (230 VAC) < 3.3 A2s (264 VAC)
Output
Short-circuit protection/overload> 4,2 A < 6.5 A
Current limitstarts at > 4.2 A
Voltage30.5 VDC ±3 % fixed
Current4 A
Residual ripple< 50 mVSS (500 kHz bandwidth, 50 &Omega, measurement, with resistive load)
Overvoltage protectedlimited to max. 55 V
Compliance with standards and directives
Directive conformity
EMC Directive 2004/108/ECEN 55022:2006, EN 55011:2009 Class B EN 61000-6-3:2001 , EN 61204-3:2001
Standard conformity
Noise immunityEN 61000-6-2:2005
Emitted interferenceEN 61000-6-3:2007 EN 61000-3-2:2010 EN 61000-3-3:2009
Galvanic isolationIEC 60364-4-41:2005 (PELV) IEC 60950:1999 (SELV)
Degree of protectionIEC 60529:2001
Pollution degreeEN 50178:1997
Mech. capacityEN 60068-2-6:2008 (Sinus) EN 60068-2-64:2009 (Random)
Shock and impact resistanceEN 60068-2-27:1995
Ambient conditions
Ambient temperature-10 ... 70 °C (14 ... 158 °F) Note derating
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Shock and impact resistance15g/6 ms 10g/11 ms
Vibration resistanceSine 2 - 17.8 Hz: ± 1.6 mm Sine 17.8 ... 500 Hz : 2 g Random 2 &hellip, 500 Hz: 0.5 m2 (s³)
Pollution degree2
Mechanical specifications
Degree of protectionIP20
Protection class1 (IEC 60536), Protective conductor connection necessary
ConnectionConnection terminals, max. conductor cross-section Flexible cable: 0.5 &hellip, 4 mm2 Rigid cable: 0.5 &hellip, 6 mm2 Stripping length 7 mm
Mass650 g
MountingDIN mounting rail