Supply of spare parts for industrial enterprises around the world
Home Brands Pepperl+Fuchs 188750 KFU8-USC-1.D

Pepperl+Fuchs KFU8-USC-1.D 188750

Signal Converter KFU8-USC-1.D Pepperl+Fuchs 188750
Manufacturer
Pepperl+Fuchs
Name
KFU8-USC-1.D
Part number
188750
Country
Germany
Type
Signal Converter
Weight (g)
213
Sale of any product from the Pepperl+Fuchs catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Pepperl+Fuchs (official website: www.pepperl-fuchs.com). We sell only certified goods and give an official guarantee from the manufacturer Pepperl+Fuchs


This signal conditioner is suitable for the connection of current and voltage signals and provides isolation for nonintrinsically safe applications. The input ranges include 0 mA ... 20 mA, 0 V... 10 V or 0 mV... 60 mV. Subranges from the input ranges are selectable. The output measuring signals are 0/4 mA ... 20 mA, 0/2 V... 10 V or 0/1 V... 5 V. The output relay serves as trip value contact. On the display the measured value can be indicated in various physical units. The unit is easily programmed by the use of a keypad located on the front of the unit. For additional information, refer to the manual and www.pepperl-fuchs.com.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications KFU8-USC-1.D 188750

General specifications
Signal typeAnalog input
Supply
Connectionterminals 14, 15
Rated voltage20 ... 90 V DC / 48 ... 253 V AC
Rated current&le, 80 mA DC / &le, 45 mA AC
Power consumption&le, 1.6 W / &le, 2.6 VA
Input
Connection sidefield side
Connectionterminals 1+, 3- : mV, V , terminals 2+, 3- : mA
Input resistancevoltage: 1 M&Omega, , current: max. 100 &Omega,
Limit30 V
Current0 ... 20 mA
Voltage0 ... 10 V / 0 ... 60 mV
Resolution15 Bit
Output
Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12 output II: terminals 7-, 8+, 9-
Output Isignal, relay
Contact loading250 V AC/2 A/cos &phi, 0.7, 40 V DC/2 A
Mechanical life2 x 107 switching cycles
Energized/De-energized delayapprox. 10 ms / approx. 10 ms
Output IIanalog
Loadcurrent: max. 550 &Omega, , voltage: min. 1 k&Omega,
Analog voltage output0/1 ... 5 V , 0/2 ... 10 V
Analog current output0/4 ... 20 mA
Transfer characteristics
Deviation0.1 % of full-scale value
Resolution/accuracycurrent: 1 µ,A/20 µ,A voltage: 0.5 mV/10 mV mV: 3 µ,V/60 µ,V
Influence of ambient temperature0.003 %/K (30 ppm)
Reaction time&ge, 150 ms/&le, 300 ms
Galvanic isolation
Input/Outputreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Indicators/settings
Display elementsdisplay
Control elementsControl panel
Configurationvia operating buttons
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage
Directive 2014/35/EUEN 61010-1:2010
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Mass150 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) , housing type B3
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.