General specifications |
Switching function | Normally closed (NC) |
Output type | NAMUR |
Rated operating distance | 8 mm |
Installation | flush |
Assured operating distance | 0 ... 6.48 mm |
Actual operating distance | 7.2 ... 8.8 mm typ. 8 mm |
Reduction factor rAl | 0.39 |
Reduction factor rCu | 0.36 |
Reduction factor r304 | 0.71 |
Output type | 2-wire |
Nominal ratings |
Nominal voltage | 8.2 V (Ri approx. 1 k&Omega,) |
Switching frequency | 0 ... 1500 Hz |
Hysteresis | 1 ... 15 typ. 5 % |
Reverse polarity protection | reverse polarity protected |
Short-circuit protection | yes |
Suitable for 2:1 technology | yes , Reverse polarity protection diode not required |
Current consumption | |
| Measuring plate not detected | min. 2.2 mA |
| Measuring plate detected | &le, 1 mA |
Switching state indicator | Multihole-LED, yellow |
Functional safety related parameters |
MTTFd | 2660 a |
Mission Time (TM) | 20 a |
Diagnostic Coverage (DC) | 0 % |
Compliance with standards and directives |
Standard conformity | |
| NAMUR | EN 60947-5-6:2000
IEC 60947-5-6:1999 |
| Electromagnetic compatibility | NE 21:2007 |
| Standards | EN 60947-5-2:2007
EN 60947-5-2/A1:2012
IEC 60947-5-2:2007
IEC 60947-5-2 AMD 1:2012 |
Approvals and certificates |
EAC conformity | TR CU 012/2011 |
FM approval | |
| Control drawing | 116-0165 |
UL approval | |
| Ordinary Location | E87056 |
| Hazardous Location | E501628 |
| Control drawing | 116-0452 |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated &le,36 V |
Ambient conditions |
Ambient temperature | -25 ... 100 °C (-13 ... 212 °F) |
Storage temperature | -40 ... 100 °C (-40 ... 212 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 4-pin |
Housing material | Stainless steel 1.4305 / AISI 303 |
Sensing face | PBT |
Degree of protection | IP66 / IP67 |
Equipment protection level Ga |
CE marking | [*PD-Z02585A*] |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga The Ex-related marking can also be printed on the enclosed label. |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety
Use is restricted to the following stated conditions |
Appropriate type | NCB8-18GM...-N0... |
Effective internal capacitance | max. 120 nF , a cable length of 10 m is considered. |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. |
Ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. Note: Use the temperature table for category 1 !!! The 20 % reduction in accordance with EN 1127-1 has already been applied to the temperature table for category 1. |
Equipment protection level Gb |
CE marking | [*PD-Z02585A*] |
ATEX marking | II 1G Ex ia IIC T6&hellip,T1 Ga
The Ex-significant identification is on the enclosed adhesive label |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety
Use is restricted to the following stated conditions |
Appropriate type | NCB8-18GM...-N0... |
Effective internal capacitance | max. 120 nF , a cable length of 10 m is considered. |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. |
Maximum permissible ambient temperature | Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the temperature class, and the effective internal reactance values can be found on the EC-type examination certificate. |
Equipment protection level Gc (ic) |
Certificate | PF 13 CERT 2895 X |
CE marking | [*PD-Z02586A*] |
ATEX marking | II 3G Ex ic IIC T6&hellip,T1 Gc
The Ex-significant identification is on the enclosed adhesive label |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection category ic Use is restricted to the following stated conditions |
Effective internal capacitance | max. 120 nF , a cable length of 10 m is considered. |
Effective internal inductance | max. 50 µ,H , A cable length of 10 m is considered.
|
Special conditions | |
| for Pi=34 mW, Ii=25 mA, T6 | 74 °C (165.2 °F) |
| for Pi=34 mW, Ii=25 mA, T5 | 89 °C (192.2 °F) |
| for Pi=34 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) |
| for Pi=64 mW, Ii=25 mA, T6 | 69 °C (156.2 °F) |
| for Pi=64 mW, Ii=25 mA, T5 | 84 °C (183.2 °F) |
| for Pi=64 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) |
| for Pi=169 mW, Ii=52 mA, T6 | 51 °C (123.8 °F) |
| for Pi=169 mW, Ii=52 mA, T5 | 66 °C (150.8 °F) |
| for Pi=169 mW, Ii=52 mA, T4-T1 | 74 °C (165.2 °F) |
| for Pi=242 mW, Ii=76 mA, T6 | 39 °C (102.2 °F) |
| for Pi=242 mW, Ii=76 mA, T5 | 52 °C (125.6 °F) |
| for Pi=242 mW, Ii=76 mA, T4-T1 | 52 °C (125.6 °F) |
Equipment protection level Gc (nL) |
Standard conformity | EN 60079-15:2003 Ignition protection category n
Use is restricted to the following stated conditions |
Effective internal capacitance Ci | max. 120 nF , a cable length of 10 m is considered. |
Effective internal inductance Li | max. 50 µ,H , A cable length of 10 m is considered.
|
General | The apparatus has to be operated according to the appropriate data in the data sheet and in this instruction manual. The data stated in the data sheet are restricted by this operating instruction!
The special conditions must be observed!
The ATEX Directive applies only to the use of apparatus under atmospheric conditions.
If you use the device outside atmospheric conditions, consider that the permissible safety parameters should be reduced. |
Special conditions | |
| for Pi=34 mW, Ii=25 mA, T6 | 74 °C (165.2 °F) |
| for Pi=34 mW, Ii=25 mA, T5 | 89 °C (192.2 °F) |
| for Pi=34 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) |
| for Pi=64 mW, Ii=25 mA, T6 | 69 °C (156.2 °F) |
| for Pi=64 mW, Ii=25 mA, T5 | 84 °C (183.2 °F) |
| for Pi=64 mW, Ii=25 mA, T4-T1 | 100 °C (212 °F) |
| for Pi=169 mW, Ii=52 mA, T6 | 51 °C (123.8 °F) |
| for Pi=169 mW, Ii=52 mA, T5 | 66 °C (150.8 °F) |
| for Pi=169 mW, Ii=52 mA, T4-T1 | 74 °C (165.2 °F) |
| for Pi=242 mW, Ii=76 mA, T6 | 39 °C (102.2 °F) |
| for Pi=242 mW, Ii=76 mA, T5 | 52 °C (125.6 °F) |
| for Pi=242 mW, Ii=76 mA, T4-T1 | 52 °C (125.6 °F) |
Equipment protection level Da |
CE marking | [*PD-Z02585A*] |
ATEX marking | II 1D Ex ia IIIC T135°C Da The Ex-related marking can also be printed on the enclosed label. |
Standards | EN 60079-0:2012+A11:2013 EN 60079-11:2012 Ignition protection Intrinsic safety
Use is restricted to the following stated conditions |
Appropriate type | NCB8-18GM...-N0... |
Effective internal capacitance | max. 120 nF A cable length of 10 m is considered. |
Effective internal inductance | max. 50 µ,H , a cable length of 10 m is considered. |
Maximum permissible ambient temperature |
Details of the correlation between the type of circuit connected, the maximum permissible ambient temperature, the surface temperature, and the effective internal reactance values can be found on the EC-type-examination certificate. The maximum permissible ambient temperature of the data sheet must be noted, in addition, the lower of the two values must be maintained. |
General information |
Use in the hazardous area | see instruction manuals |
| Category | 1G, 2G, 3G, 1D |