Supply of spare parts for industrial enterprises around the world

IFM SM7000

  IFM SM7000
Manufacturer
IFM
Part number
SM7000
Country
Germany
Sale of any product from the IFM catalog at competitive prices

2technologie will help you choose and buy products and spare parts from IFM (official website: www.ifm.com). We sell only certified goods and give an official guarantee from the manufacturer IFM


This is flow meter with a measuring range of 0.2-50 l/min and totaliser function ensures high accuracy, repeatability and measurement dynamics. Thanks to the flat-seal process connection G 3/4, M12 connector and flexible programming via pushbuttons can be adapted to the respective application. Used for flow rate measurement of conductive media, e.g. coolants in welding equipment.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications SM7000

< tr>< th>Response time< /tr>< tr>
Application
ApplicationSum function, for general industrial use
Installationpipe connection with adapter
MediumConductive liquids, Water, water-based liquids
Medium note
Conductivity: ? 20 µS/cm
Viscosity: < 70 mm?/s (40 °C)
Measured medium temperature [°C]-10…70
Pressure strength [bar] 16
MAWP (for use according to CRN) [bar]11.2
Electronic data
Operating voltage [V]18…30 DC, (according to EN 50178 SELV/PELV )
Current consumption [mA]95, (24 V)
Protection class< /td>III
Reverse polarity protectionyes
Power-on delay time [s]5
Inputs/outputs
Number of inputs and outputs Number of digital outputs: 2, Number of analog outputs: 1
Inputs
Inputsreset counter
Outputs
Total number of outputs2
Output signalSwitching signal analog New signal, pulse signal, IO-Link, (configurable)
Electrical versionPNP/NPN
Number of digital outputs2
Output signal functionnormally open / normally closed, (parameterizable)
Max. voltage drop DC switching output [V]2
DC switching output load current [mA]200
Number of analog outputs1
Analog current output [mA] 4…20, (scalable)
Max. load [?]500
Analog voltage output [V]0…10, (scalable)
Min. load resistance [?]2000
Pulse outputFlowmeter
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Measurement/setting range
Range measurements
0.2…50 l/min0.01…3 m?/h
Display range
-60…60 l /min-3.6…3.6 m?/h
Resolution
0.1 l/min0.001 m?/h
Setting point SP
0.5…50 l/min< /td>0.027…3 m?/h
Reset point rP
0.2…49.8 l/min0.012…2.985 m?/h
Analog start point, A SP
0…40 l/min0…2.4 m?/h
Analogue end point, AEP
10…50 l/min0.6…3 m?/h
Width step
0.1 l/min0.001 m?/h
Momentary flow control
Pulse value0.00001 …50 000 m?
Pulse length [s]0.005…2
Temperature control
Measuring range [°C]-20…80
Resolution [ °C]0.2
Setting point SP [°C]-19.2…80
Reset point rP [°C]-19.6…79.6
Analog start point [°C]-20…60
A tax endpoint [°C]0…80
In steps of [°C]0.2
Accuracy/Uncertainty
Flow rate control
Accuracy (in measuring range)± (0.8 % MW + 0, 5% MEW)
Repeatability± 0.2% MEW
Control temperature
Accuracy [K]± 2.5 (Q > 5 l/min)
Flow rate control
Response time [s] 0.15, (dAP = 0)
Programmable delay time dS, dr [s]0…50
Switching output damping dAP [s]0…5
Temperature monitoring
Trip response time T05 / T09 [s]T09 = 20 (Q > 5 l/min)
Software / Programming
Parameter selectionFlow control, flow meter, pre-set counter, Temperature control, hysteresis/window, normally open/normally closed, switching logic, current output/voltage output/pulse output, Start delay, display can be switched off, Display
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO-Link test1.1
SDCI StandardIEC 61131-9
IO-Link Device ID572 / 00 02 3c
ProfilesSmart Sensor: Process Data Variable, Device Identification, Device Diagnosis
SIO modeyes
Desired port typeA
Analog operating data3
Binary operating data2
Minimum operating cycle time [ms]5
Operating conditions
Temperature Ambient temperature [°C]-10…60
Storage temperature [°C]-25…80< /td>
Degree of protectionIP 67
Tests / approvals
EMC
DIN EN 60947-5-9
Impact resistance
DIN IEC 68-2-27 20 g (11 ms)
Vibration resistance
DIN IEC 68-2-65 g (10…2000 Hz)
MTTF [years]145
Pressure Equipment DirectiveGood engineering practice, can be used for fluid group 2, fluid group 1 on request
Mechanical data
Weight [g ]587
Materialstainless steel steel (1.4404 / 316L), PBT-GF20, PC, FKM, TPE mediumstainless steel steel (1.4404 / 316L), PEEK, FKM
Process connectionThreaded connection G 3/4 DN20 Flat seal
Displays / Controls
Display< td>2 x LED, yellow< td>programming
Display 6 x LED, green (l/min, m?/h, l, m?, 10?, °C)
Output status
Measured valuesalphanumeric display, 4 digits
alphanumeric display, 4 digits
Notes< /th>
Notes
MW = Measured value
MEW = Upper limit of measuring range
Pack quantity1 piece< /td>
electrical connection
ConnectionConnector: 1 x M12, Contacts: gold-plated
Diagrams and Graphs
Pressure Loss
dPPressure loss
Qvolumetric consumption