Application |
---|
Application | Sum function, for general industrial use |
Installation | pipe connection with adapter |
Medium | Conductive liquids, Water, water-based liquids |
Medium note | Conductivity: ? 20 µS/cm | Viscosity: < 70 mm?/s (40 °C) |
|
Measured medium temperature [°C] | -10…70 |
Pressure strength [bar] | 16 |
MAWP (for use according to CRN) [bar] | 11.2 |
Electronic data |
---|
Operating voltage [V] | 18…30 DC, (according to EN 50178 SELV/PELV ) |
Current consumption [mA] | 95, (24 V) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 5 |
Inputs/outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2, Number of analog outputs: 1 |
Inputs |
---|
Inputs | reset counter |
Outputs |
---|
Total number of outputs | 2 |
Output signal | Switching signal analog New signal, pulse signal, IO-Link, (configurable) |
Electrical version | PNP/NPN |
Number of digital outputs | 2 |
Output signal function | normally open / normally closed, (parameterizable) |
Max. voltage drop DC switching output [V] | 2 |
DC switching output load current [mA] | 200 |
Number of analog outputs | 1 |
Analog current output [mA] | 4…20, (scalable) |
Max. load [?] | 500 |
Analog voltage output [V] | 0…10, (scalable) |
Min. load resistance [?] | 2000 |
Pulse output | Flowmeter |
Short-circuit protection | yes |
Short-circuit protection type | clocked |
Overcurrent protection | yes |
Measurement/setting range |
---|
Range measurements | |
Display range | -120…120 l /min | -7.2…7.2 m?/h |
|
Resolution | |
Setting point SP | |
Reset point rP | 0.2…99.5 l/min | 0.01…5.97 m?/h | < /tr>
|
The starting point of the analog signal, ASP | |
Analogue end point, AEP | |
Width step | |
Momentary flow control |
---|
Pulse value | 0.00001 …100 000 m? |
Pulse length [s] | 0.0025…2 |
Temperature control |
---|
Measuring range [°C] | -20…80 |
Resolution [°C] | 0.2 |
Setting point SP [°C] | -19.2…80 |
Reset point rP [°C] | -19.6…79.6 |
Analog start point [°C] | -20…60 |
Analogue end point [°C] | 0…80 | 0…80 |
| |
In steps of [°C] | 0.2 |
Accuracy/Uncertainty |
---|
Flow rate control |
---|
Accuracy (in measuring range) | ± (0.8 % MW + 0.5% MEW) |
Repeatability | ± 0.2% MEW |
Temperature control |
---|
Accuracy [K] | ± 2.5 (Q > 5 l/min) |
Response Time |
---|
Flow Rate Control |
---|
Response time [s] | 0.15, (dAP = 0) |
Programmable delay time dS, dr [s] | 0…50 |
Switching output damping dAP [s] | 0…5 |
Temperature control |
---|
Dynamics of response response T05 / T09 [s] | T09 = 20 (Q > 5 l/min ) |
Software / Programming |
---|
Parameter selection | Flow rate control, flow meter, counter with presetting, Temperature control, hysteresis / window, normally open / normally closed, switching logic, current output / voltage output / pulse output, Start delay, display can be switched off, Display |
Interfaces |
---|
Communication interface | IO-Link |
Transmission method | COM2 (38.4 kBaud) |
IO-Link test | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link Device ID | 575 / 00 02 3f |
Profiles | Smart Sensor: Process Data Variable, Device Identification, Device Diagnosis |
SIO mode | yes |
Desired port type | A |
Analog operating data | 3 |
Binary operating data | 2 |
Min. cycle time [ms] | 5 |
Operating conditions |
---|
Ambient temperature [°C] | -10…60 |
Storage temperature [°C] | -25…80 |
Degree of protection | IP 67 |
Tests / approvals |
---|
EMC | |
Impact resistance | DIN IEC 68-2-27 | 20 g (11 ms) |
|
Vibration resistance | DIN IEC 68-2-6 | 5 g (10…2000 Hz) |
|
MTTF [g Code] | 145 |
Pressure Equipment Directive | Good engineering practice, can be used for fluid group 2, group liquids 1 on request |
Mechanical data |
---|
Weight [g] | 641.5 |
Material | stainless steel steel (1.4404 / 316L), PBT-GF20, PC, FKM, TPE medium | stainless steel steel (1.4404 / 316L), PEEK, FKM |
Process connection | G 1 DN25 threaded connection Flat seal |
Displays / Controls |
---|
Display | Display | 6 x LED, green (l/min, m?/h, l, m?, 10?, °C) | Output status | 2 x LED, yellow | Measured values | alphanumeric display, 4 digits | programming | alphanumeric display, 4 digits |
|
Notes |
---|
Notes | MW = Measured value | MEW = Upper limit of measuring range |
|
Pack quantity | 1 piece |
electrical connection |
---|
Connection | Connector: 1 x M12, Contacts: gold-plated |
Diagrams and Graphs |
---|
Pressure Loss | dP | Pressure loss |
---|
Q | volumetric consumption |
---|
|
---|