Application |
---|
Media | Liquids, Gases |
Measured medium temperature [°C] | -25…80 |
Pressure strength [bar] | 300 |
Liquid media |
---|
Measured medium temperature [°C] | -25… 80 |
Gases |
---|
Measured medium temperature [°C] | -25… 80 |
Electronic data |
---|
Operating voltage [V] | 18…36 DC |
Current consumption [mA] | <60 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 10 |
Inputs/outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | Switching signal, IO-Link, (configurable ) |
Electrical version | PNP |
Number of digital outputs | 2 |
Output function | normally open / normally closed, (parameterizable) |
Max. voltage drop of switching output DC [V] | 2.5 |
DC load current of switching output DC [mA] | 250 |
Short-circuit protection | yes |
Short-circuit protection type | clocked |
Overcurrent protection | yes |
Measurement/setting range |
---|
Probe length L [mm] | 45 |
Liquids |
---|
Parameter setting within [cm/s] | 3…300 |
Max. sensitivity [cm/s] | 3…100 |
Gases |
---|
Parameter setting within [cm/s] | 200…3000 |
Max. sensitivity [cm/s] | 200…800 |
Temperature control |
---|
Range measurement [°C] | 2…80 |
Resolution [°C] | 1 |
Accuracy/Uncertainty |
---|
Reproducibility [cm/s] | 1…5 |
Repeatability note | for water 5…100 cm/s, 25 °C | Factory setting |
|
Temperature drift [cm/s x 1/K] | 0.1, (for water 5…100 cm/s, 10…70 °C) |
Max. temperature gradient (rate of change of medium temperature) [K/min] | 300 |
Switch point error [cm/s] | ± 2…± 10, (for water 5…100 cm/s , 25 °C, factory setting) |
Hysteresis [cm/s] | 2…5, (for water 5…100 cm/s, 25 °C, Factory setting) |
Temperature control |
---|
Switch point error [K] | ± 3 (v> 5cm/s), (Liquid media) |
Resolution [K] | 1 |
Reproducibility [K] | 2 |
Response time |
---|
Response time [s] | 1…10 |
Liquids |
---|
Response time [s] | 1…10 |
Gases |
---|
Response time [s] | 1…10 |
Temperature control |
---|
Response time [s] | 1…10 |
Software / Programming |
---|
Switch point setting | Programming buttons |
Interfaces |
---|
Communication interface | IO-Link |
Transmission method | COM2 (38.4 kBaud) |
IO-Link test | 1.1 |
SDCI standard | IEC 61131-9 |
IO-Link Device ID | 53 d / 00 00 35 h |
Profiles | Smart Sensor: Process Data Variable , Device Identification |
SIO Mode | yes |
Desired port type | A |
Analog operating data | 2 |
Binary operating data | 2 |
Min. cycle time [ms] | 3 |
Operating conditions th> |
---|
Ambient temperature [°C] | -25…80 |
Storage temperature [°C] | -25…100 |
C degree of protection | IP 65, IP 67 |
Tests / approvals |
---|
EMC | |
Impact resistance | DIN IEC 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN EN 60068-2-6 | 20 g (55…2000 Hz) |
|
MTTF [years] | 277 |
Mechanical data |
---|
Weight [g] | 254 |
Dimensions [mm] | M18 x 1.5 |
Designation threads | M18 x 1.5 |
Material | stainless steel steel (1.4404 / 316L), stainless steel steel (1.4310 / 301), PC, PBT-GF20, EPDM/X medium | stainless steel steel (1.4404 / 316L), O-ring: FKM 80 Shore A |
Process connection | M18 x 1.5 internal thread |
Displays / Controls |
---|
Display | Function | 10 x LED, 3-color |
|
Notes |
---|
Packing quantity | 1 piece |
Electrical connection |
---|
Connection | Connector: 1 x M12 |