Application |
---|
Media | liquid refrigerants, oils, oily media, Water, water-like media |
Dielectric constant of the medium | ? 2, (for medium with a dielectric constant of 2 to 20 (e.g. oils), a coaxial pipe is required for operation) |
It is forbidden to use lubricants for | , granulates, bulk solids, acids, alkalis, strongly foaming media |
Measured medium temperature [°C] | 0…80, (90 < 1 h ) |
Reservoir pressure [bar] | -1…16 |
MAWP (for application according to CRN) [bar] | 25 |
Electronic data |
---|
Operating voltage [V ] | 18…30 DC |
Current consumption [mA] | < 80 |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | < 3 |
Inputs/outputs |
---|
Number of inputs and outputs | Number of digital outputs: 1, Number of analog outputs: 1 |
Outputs |
---|
Total number of outputs | 2 | < /tr>
Output signal | Switching signal, analogue signal, IO-Link |
Electrical version | PNP |
Number of digital outputs | 1 |
Output function | normally open / normally closed, (parameterizable) |
Max. voltage drop DC switching output [V] | 2.5 |
DC switching output load current [mA] | 200 |
Number of analog outputs | 1 |
Analog current output [mA] | 4…20 |
Maximum load [?] | 500 |
Analog output according to voltage [V] | 0…10 |
Min. load resistance [?] | 2000 |
Short circuit protection | yes |
Type of short-circuit protection | Temperature, synchronized |
Overcurrent protection | yes | < /tr>
Measuring/setting range |
---|
Probe length L [mm] | 100…1600 |
Active range A [mm] | L-40 (L-60), (when adjusted for oil or oily media) |
Inactive area I1 / I2 [mm] | 30 / 10 (30), (when adjusted for oil or oily media) |
Parameter setting within |
---|
Switching point SP [mm] | ? 15 (35) / ? L-30 |
Note on setting point SP | when setting for oil or oil containing media | | Reset point rP [mm] | ? 10 (30) / ? L-35 | Note on reset point rP | when setting for oil or oily fluids |
| In increments of [mm] | 5 | Hysteresis [mm] | 5 | Accuracy/Uncertainty |
---|
Repeatability [mm] | ± 5 | Switch point error [mm] | ± (15 + 0.5 %), (% of measuring range limit: L - 30 mm) | Deviation from specification | ± 10 | Displacement error [mm] | 10 | Sensitivity | 16 mA ? MEW10V? MEW | Resolution [mm] | 0.5 (L 300 mm) | Zero signal (voltage) [V] | 0…0.02 | Zero signal (current) [mA] | 3.95 …4.0 | Total signal (voltage) [V] | 10.0…10.1 | Total signal (current) [mA] | 20…20.2 | Interfaces |
---|
Communication interface | IO-Link | Transmission method | COM2 (38.4 kBaud) | < /tr> IO-Link test | 1.1 | SDCI standard | IEC 61131-9 CDV | IO-Link Device ID | 344 d / 00 01 58 h | Profiles | no | SIO mode | yes | Desired port type | A | Analog operating data | 1 | Binary operating data | 1 | Min. cycle time [ms] | 2.3 | Operating conditions |
---|
Ambient temperature [°C] | 0…60 | Storage temperature [°C] | -25…80 | Degree of protection | IP 67 | Tests / approvals |
---|
EMC | | Shock resistance | DIN IEC 68-2-27 | 50 g (11 ms) | < /tbody>
| Vibration resistance | DIN IEC 68-2-6 | 5 g (10…2000 Hz) |
| MTTF [years] | 174.71 | Mechanical data |
---|
Weight [g] | 384 | Material | stainless steel steel (1.4301/304), FKM, PBT (polybutylene terephthalate), PC, PEI, TPE-V, PTFE (teflon) | Body materials in contact with meas. medium | stainless steel steel (1.4305/303), sensor connection: stainless steel steel (1.4435 / 316L), PTFE (Teflon), FKM, Seal: NBR-PPTA 20 | Process connection | G 3/4 external thread | Displays / Controls |
---|
Display | Display | 3 x LED, green | Output status | 1 x LED, yellow | Fill level | alphanumeric display, 4-digit | parameterization | alphanumeric display , 4-digit |
| Accessories |
---|
Accessories (optional) | Probe:, E43203…E43205 / E43207…E43210 | Coaxial tube:, E43211…E43221, E43223, E43224 |
| Notes |
---|
Packing quantity | 1 piece | Electrical connection |
---|
Connection | Connector: 1 x M12, Contacts: gold-plated |
|