Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 159614 CTP-I-AP-U-HA-ZZE-SBB-159614

Euchner CTP-I-AP-U-HA-ZZE-SBB-159614 159614

 CTP-I-AP-U-HA-ZZE-SBB-159614 Euchner 159614
Manufacturer
Euchner
Name
CTP-I-AP-U-HA-ZZE-SBB-159614
Part number
159614
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 159614 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 159614 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 159614 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 159614 spares for all applications.

  • Swift Delivery: Quick access to Euchner 159614 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 159614 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 159614 Industrial components.

Order Euchner 159614 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CTP-I-AP-U-HA-ZZE-SBB-159614 159614

  • Safety switch without guard locking, with integrated evaluation electronics
  • Direct connection to decentralized peripheral systems (e.g. ET 200 pro)
  • Short circuit monitoring
  • Two safety outputs (semiconductor outputs)
  • Up to category 4/PL e according to EN ISO 13849-1
  • With two plug connectors M12
  • Unicode
  • Emergency stop
  • Approach directions A, B and C (delivery state)
Approach direction Horizontal Can be adjusted in 90° steps Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connecting cable
X 1.1 UB Electronics operating voltage 24 V DC BN
X 1.2 FO1A Safety output, channel 1 WH
X 1.3 0 V UB Electronics operating voltage 0 V BU
X 1.4 FO1B Safety output, channel 2 BK
X 1.5 - n.c. GY
X 2.1 S1.A1 EMERGENCY STOP (channel A) BN
X 2.2 S1.B1 EMERGENCY STOP (channel B) WH
X 2.3 - n.c. BU
X 2.4 S1.A2 EMERGENCY STOP (channel A) BK
X 2.5 S1.B2 EMERGENCY STOP (channel B) GY
Housing material
Safety switch housing Fiber glass reinforced thermoplastic
Switch head cover Die-cast zinc
Weight
Net 0,23 kg
Ambient temperature
At UB = 24V DC -20 ... +55 °C
Degree of protection IP65
Resilience to vibration In acc. with EN IEC 60947-5-3
Mechanical life 1 x 106
Installation orientation Any
Ready delay max.1 s
Switching frequency max.0,5 Hz
Connection 2 plug connectors M12, 5-pin
Approach speed 20 m/min
Extraction force 20 N
Actuating force 10 N
Overtravel 5 mm
Electrical connection ratings
Test-pulse interval min.100 ms
Test pulses max.0,3 ms
Operating voltage DC
UUB 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV
Current consumption
IUB 40 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage UB) 0,25 ... 2 A
Rated insulation voltage Ui max.50 V
Rated impulse withstand voltage Uimp max.0,5 kV
Power consumption 1 W
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Safety class
EN IEC 61140 III
Switching load
According to UL 24V DC, class 2
Safety outputs FO1A / FO1B
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
Per safety output FO1A / FO1B 1 ... 150 mA
Output voltage
High U(FO1A) / U(FO1B) UB-1,5 ... UB V DC
Low U(FO1A) / U(FO1B) 0 ... 1 V DC
Off-state current Ir max.0,25 mA
Switch-on time max.400 ms
Discrepancy time
Both safety outputs max.10 ms In acc. with EN IEC 60947-5-3
Emergency stop
Operating voltage 5 ... 24 V
Operating current 1 ... 100 mA
Work area
Repeat accuracy R 10 %
Controls and indicators
Position 1
Ausfuhrung Emergency stop
Einlegeschild
Extras
Farbe
Schaltelement 2 pos. driven NC
Other
Detent mechanism Snap-in bolt
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures see operating instructions
Reliability values according to EN ISO 13849-1
Emergency stop
B10D 0,065 x 106
Performance Level PL e
Category 4
PFHD 4.1 x 10 -9
Mission time 20 y