Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 162596 CES-I-AR-M-C14-U20-162596

Euchner CES-I-AR-M-C14-U20-162596 162596

 CES-I-AR-M-C14-U20-162596 Euchner 162596
Manufacturer
Euchner
Name
CES-I-AR-M-C14-U20-162596
Part number
162596
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 162596 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 162596 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 162596 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 162596 spares for all applications.

  • Swift Delivery: Quick access to Euchner 162596 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 162596 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 162596 Industrial components.

Order Euchner 162596 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CES-I-AR-M-C14-U20-162596 162596

  • Safety switch with integrated evaluation electronics
  • Safety switch CES-C04 encapsulated in epoxy resin
  • Tested for material resistance in accordance with Ecolab specifications
  • Up to 20 switches in series
  • Two safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connecting cable PUR, 20 m, with cable end sleeves
  • Multicode
  • Monitoring output OD
Installation position Permissible installation position Attention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBN) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 10 mm must be maintained so that the operating distance of the side lobes is not entered. Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category according to EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostic LED
Terminal assignment
Designation Function Conductor coloring of connecting cable
FI1B Enable input for channel 2 WH
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 GN
FO1B Safety output, channel 2 YE
OD Monitoring output GY
FI1A Enable input for channel 1 PK
0V Ground, DC 0 V BU
RST Reset input RD
Housing material Two-component epoxy resin
Weight
Net 0,7 kg
Ambient temperature
Cable static -40 ... 80 °C
At UB = DC 24 V 0 ... +50 °C
Cable dynamic -25 ... 80 °C
Degree of protection IP65 / IP67 / IP69 / IP69K
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.150 mm
Installation orientation Any
Tightening torque
Fixing screws 2 Nm
Ready delay 10 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.400 ms
Safety class III
Risk time according to EN 60947-5-3
Delay per device max.260 ms
Monitoring output OD
Type of output Monitoring, semiconductor output, p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.1,0 ms
Test-pulse interval min.140 ms
Type of output 2 semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 200 mA
Output voltage
HIGH U (FO1A1) / U (FO1B) UB-1,5V ... UB V DC
LOW U (FO1A1) / U (FO1B) 0 ... 1 V DC
Utilization category according to EN 60947-5-2
DC-13 24 V 150 mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BBN-C14-160441Operating distance
Switch-on distance
Installation position D / in z direction max.23 mm ALU
max.18 mm PVC
Installation position A / in z direction max.24 mm ALU
max.22 mm PVC
Assured switch-off distance Sar
Installation position D / in y direction max.68 mm
Installation position D / in x/z direction max.58 mm
Installation position A / in y direction max.72 mm
Installation position A / in x/z direction max.64 mm
Assured operating distance Sao
Installation position D / in z direction max.5 mm PVC
Installation position A / in z direction max.10 mm ALU
max.11 mm PVC
Installation position D / in z direction max.6 mm ALU