- With protective plate
- Suitable for use in zones 2 and 22 (gases and dusts)
- Safety switches as interlocking device of type 4
- Safety switch with integrated evaluation electronics
- Possible to switch pulsed signals
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
Approach directionCan be adjusted in 90° steps Protective plateA protective plate included protects the safety switch against impacts on the housing and the ingress of a potentially explosive atmosphere. Each actuator is unique. The evaluation unit detects only the actuator that has been taught-in. Additional actuators can be taught in. Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- CES-A-C5H-01, category 4 / PL e according to EN ISO 13849-1
LED indicator
STATE | Status LED |
OUT/ERROR | Safety outputs status / diagnostics LED (combined) |
Additional connections
OUT | Monitoring output (semiconductor) |
Attention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBA, CES-A-BCA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the operating distance of the side lobes is not entered. (Only in combination with actuator CES-A-BPA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Dimension drawing Wiring diagram (View of connection side on the safety switch) Dimension drawingWiring diagram(View of connection side on the safety switch) Technical dataApprovals Mechanical values and environment
Dimensions | According to EN 60947-5-2 |
Housing material | Plastic PBT V0 GF30 |
Weight | 0,4 kg |
Ambient temperature | |
At UB = 24 V DC | -20 ... 50 °C |
Degree of protection | IP67 |
Mounting distance | |
Between 2 read heads or 2 actuators | min.80 mm |
Installation orientation | Any |
Tightening torque | |
Screws fastening bracket read head | max.0,6 Nm |
Fixing screws housing | max.1 Nm |
Ready delay | max.3 s |
Reaction time | |
After change in the actuation status | max.180 ms |
Switching frequency | max.1 Hz |
Dwell time | min.0,5 s |
Connection | M12 plug connector, 8-pin, screen can be applied |
Electrical connection ratings
Operating voltage DC | 21 ... 24 ... 27 V DC Regulated, residual ripple < 5 % |
Current consumption | 80 mA |
Fusing | |
(External) operating voltage | 0,25 ... 8 A |
Rated insulation voltage Ui | max.300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
| STATE LED |
LED indicator | Status LED |
| OUT / ERROR |
LED indicator | Safety outputs status / diagnostics LED (combined) |
| Safety outputs LA / LB |
Type of output | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled |
Output voltage | |
LOW U(LA) / U(LB) | 0 ... 1 V DC |
HIGH U(LA) | U(+LA) - 1,5 ... U(+LA) V DC |
HIGH U(LB) | U(+LB) - 1,5 ... U(+LB) V DC |
Output current | |
per safety output | 1 ... 100 mA |
Fusing | |
External, safety circuit U(+LA) / U(+LB) | 0.1 A medium slow-blow |
Switching load | |
According to UL | max. DC 24 V, class 2 |
Rated conditional short-circuit current | max.100 A |
Discrepancy time | |
(Between the operating points of both safety outputs) | max.120 ms |
Power supply output load | |
U(+LA) / U(+LB) | 24 V DC 18 ... 27 V DC |
| Monitoring output OUT |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0,8 x UB ... UB V DC |
Output current | max.20 mA |
Work area
Repeat accuracy R | max.10 % |
Other
Explosion protection | |
incl. cover | II3G Ex ic ec IIB T5 Gc X / II3D Ex ic tc IIIC T90°C Dc X |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Reliability values according to EN ISO 13849-1
| Monitoring of the safety guard position |
Category | 4 |
Performance Level | |
PL e | |
PFHD | 3.7 x 10-9 |
Diagnostic Coverage (DC) | 99 % |
Mission time | 20 y |
In combination with Actuator CES-A-BPA-EXOperating distance
Distance s, actuator | |
Minimum distance for side approach direction | min.6 mm |
Switch-on distance | |
With center offset m=0 | 22 mm |
Assured switch-off distance Sar | max.58 mm |
Assured operating distance Sao | |
With center offset m=0 | min.15 mm |
Switching hysteresis | min.1 mm |
In combination with Actuator CES-A-BBA-EXOperating distance
Distance s, actuator | |
Minimum distance for side approach direction | min.4 mm |
Switch-on distance | |
With center offset m=0 | 20 mm |
Assured switch-off distance Sar | max.40 mm |
Assured operating distance Sao | |
With center offset m=0 | min.18 mm |
Switching hysteresis | min.2 mm |