- Auxiliary release on the front
- With door monitoring contact
- Increased horizontal overtravel
Approach direction Horizontal and vertical Can be adjusted in 90° steps Increased overtravel for horizontal approach direction Solenoid operating voltage
LED function displayA function display (2 LEDs, red and green) is available for the following voltage range:
Guard locking type
TP3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
Switching element
4131 | Slow-action switching contact 2 NC + 1 NO + 1 NO (door monitoring contact) |
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 2 |
Number of NO contacts | 2 |
Connection | |
3 x | M20 x 1.5 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Retention force | 10 N |
Extraction force | 20 N |
Actuating force | 10 N |
Electrical connection ratings
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
Display module | |
AC/DC | 24 V -15% ... +10% |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
B10D | 3 x 106 |
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
Overtravel A B C D E | 2 mm |
Overtravel K L M N | 1,5 mm |
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
Overtravel A B C D E | 7 mm |