- Safety switch with integrated evaluation electronics
- Possible to switch pulsed signals
- 2 safety outputs (semiconductor outputs)
- Category 4/PL e according to EN ISO 13849-1
- Multicode
Approach directionCan be adjusted in 90° steps Multicode evaluationEvery suitable actuator is detected by the evaluation unit. Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN ISO 13849-1
LED indicator
STATE | Status LED |
OUT/ERROR | Safety outputs status / diagnostics LED (combined) |
Additional connection
OUT | Monitoring output (semiconductor) |
Attention:The operating distance may vary depending on the background material and installation situation. (Only in combination with actuator CES-A-BBA, CES-A-BCA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 4 mm must be maintained so that the operating distance of the side lobes is not entered. (Only in combination with actuator CES-A-BPA) Typical operating distance For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered.
Dimensions | According to EN 60947-5-2: (LxWxH) 131x40x40 |
Housing material | Plastic, PBT |
Weight | |
Net | 0,4 kg |
Ambient temperature | |
At UB = 24 V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Mounting distance | |
Between 2 switches or 2 actuators | min.80 mm |
Installation orientation | Any |
Tightening torque | |
Screws fastening bracket read head | max.0,6 Nm |
Fixing screws housing | max.1 Nm |
Ready delay | max.3 s |
Reaction time | |
After change in the actuation status | max.180 ms |
Switching frequency | max.1 Hz |
Dwell time | min.0,5 s |
Connection | M12 plug connector, 8-pin, screen can be applied |
Electrical connection ratings
Operating voltage DC | 18 ... 24 ... 27 V DC Regulated, residual ripple < 5 % |
Current consumption | 80 mA |
Fusing | |
(External) operating voltage | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
| Safety outputs LA / LB |
Type of output | Semiconductor outputs, p-switching, short circuit-proof, electrically decoupled |
Output voltage | |
HIGH U(LA) | U(+LA) - 1,5 ... U(+LA) V DC |
HIGH U(LB) | U(+LB) - 1,5 ... U(+LB) V DC |
LOW U(LA) / U(LB) | 0 ... 1 V DC |
Output current | |
per safety output | 1 ... 400 mA |
Fusing | |
External, safety circuit U(+LA) / U(+LB) | 0.4 A medium slow-blow |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 400mA |
Switching load | |
According to UL | max. DC 24 V, class 2 |
Rated conditional short-circuit current | max.100 A |
Discrepancy time | |
(Between the operating points of both safety outputs) | max.120 ms |
Power supply output load | |
U(+LA) / U(+LB) | 24 V DC 18 ... 27 V DC |
| Monitoring output OUT |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Output voltage | 0,8 x UB ... UB V DC |
Output current | max.20 mA |
| STATE LED |
LED indicator | Status - LED |
| LED OUT / ERROR |
LED indicator | Safety outputs status / diagnostics (combined) |
Work area
Repeat accuracy R | max.10 % |
Other
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Reliability values according to EN ISO 13849-1
| Monitoring of the safety guard position |
Category | 4 |
Performance Level | PL e |
PFHD | 3.7 x 10-9 |
Diagnostic Coverage (DC) | 99 % |
Mission time | 20 y |
In combination with Actuator CES-A-BBA, CES-A-BCAOperating distance
Distance s, actuator | |
Minimum distance for side approach direction | min.3 mm |
Switch-on distance | |
With center offset m=0 | 20 mm |
Assured switch-off distance Sar | max.40 mm |
Assured operating distance Sao | |
With center offset m=0 | min.18 mm |
Switching hysteresis | min.2 mm |
In combination with Actuator CES-A-BPAOperating distance
Distance s, actuator | |
Minimum distance for side approach direction | min.6 mm |
Switch-on distance | |
With center offset m=0 | 22 mm |
Assured switch-off distance Sar | max.58 mm |
Assured operating distance Sao | |
With center offset m=0 | min.15 mm |
Switching hysteresis | min.1 mm |
In combination with Actuator CES-A-BDA-20Operating distance
Distance s, actuator | |
Minimum distance for side approach direction | min.4 mm |
Switch-on distance | |
With center offset m=0 | 21 mm |
Assured switch-off distance Sar | max.41 mm |
Assured operating distance Sao | |
With center offset m=0 | min.19 mm |
Switching hysteresis | min.2 mm |