- Up to 30 read heads can be connected
- 1 safety contact
Functional The evaluation unit CMS-E-AR is suitable for the direct connection of up to 30 read heads. Category/PL according to EN ISO 13849-1
- Category 1/PL c with 3 ... 30 read heads connected (NO contacts wired in series)
- Category 3/PL d with 1 ... 2 read heads connected (NO contacts wired in parallel)
Dimension drawing Wiring diagram CMS: Magnetically coded safety switches Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material | Polycarbonate (PC) |
Weight | |
Net | 0,13 kg |
Ambient temperature | 0 ... 50 °C |
Degree of protection | Terminals IP20 / housing IP40 |
Mechanical life | 10 x 106 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Connection | Connection terminals, plug-in |
| Safety contacts 13/14 |
Number of safety contacts | 1 |
Electrical connection ratings
Operating voltage | |
DC | 24 V -10% ... +10% |
Fusing | |
Protection internal (operating voltage UB) | 0,75 A Automatically resetting fuse PTC |
Rated insulation voltage Ui | |
AC | 250 V |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm? |
LED indicator | 1 indicator LED Power (UB) and 2 status indicators for the read heads (D1/D2) |
| Safety contacts 13/14 |
Type of output | Relay contacts, floating |
Current consumption | 70 mA |
Switching voltage | |
AC | max.250 V |
Switching current | |
at DC 24V | 2 ... 3000 mA |
Fusing | |
External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 3A gG |
Utilization category according to EN 60947-4-1 | |
Utilization category according to EN 60947-5-1 | |
AC-15 | 0.9A , 250V |
DC-13 | 1.8A , 24V |
Switching load | |
According to UL class 2 | Input: 24V DC , output: 24V DC |
Breaking capacity (VA) | max.750 VA |
Risk time according to EN 60947-5-3 | 10 ms |
Other
In compliance with | EN ISO 13849-1: 2015 , EN 50178: 1997 , EN 60204-1: 2006/A1: 2009 , EN ISO 14119: 2013, EN 6100-6-2: 2005, EN 6100-6-3: 2007/A1:2011, EN 60947-5-3: 2013 |
Reliability values according to EN ISO 13849-1
| Monitoring of the safety guard position |
Category | |
More than 2 read heads with serial wiring | 1 |
With up to 2 read heads with parallel wiring | 3 |
Performance Level | |
With up to 2 read heads with parallel wiring | PL d |
With more than 2 read heads with serial wiring | PL c |
PFHD | |
With up to 2 read heads with parallel wiring | 4.3 x 10-8 |
With more than 2 read heads with serial wiring | 1.1 x 10-6 |
Number of switching cycles | |
? 1A at 24V DC | max.75000 1/Jahr |
? 3A at 24V DC | max.18000 1/Jahr |
? 0.1A at 24V DC | max.96000 1/Jahr |
Mission time | 20 y |
In combination with Read head CMS-R-BXO-05V, CMS-R-BXP-05V, CMS-R-BXO-SC, CMS-R-BXP-SC, CMS-R-BXO-05P and Actuator CMS-M-BHOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.17 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-R-CXA-03V, CMS-R-CXB-03V, CMS-R-CXA-05V, CMS-R-CXB-05V, CMS-R-CXB-SC, CMS-R-CXA-05P and Actuator CMS-M-CAOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.16 mm |
Assured operating distance Sao | |
With center offset m=0 | min.7 mm |
In combination with Read head CMS-R-AXE-03V, CMS-R-AXG-03V, CMS-R-AXE-05V, CMS-R-AXG-05V, CMS-R-AXE-SC, CMS-R-AXG-SC, CMS-R-AXE-01V, CMS-R-AXE-05P and Actuator CMS-M-AGOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.34 mm |
Assured operating distance Sao | |
With center offset m=0 | min.18 mm |
In combination with Read head CMS-R-AXD-03V, CMS-R-AXF-03V, CMS-R-AXD-05V, CMS-R-AXD-SC, CMS-R-AXF-05P, CMS-R-AXF-SC, CMS-R-AXF-05V and Actuator CMS-M-ABOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.18 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-R-EXL-03V, CMS-R-EXM-03V, CMS-R-EXN-03V, CMS-R-EXL-05V, CMS-R-EXN-05V and Actuator CMS-M-EFOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.16 mm |
Assured operating distance Sao | |
With center offset m=0 | min.7 mm |
In combination with Read head CMS-R-AXR-05VL and Actuator CMS-M-AIOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.23 mm |
Contact status indication with LED | max.15 mm |
Assured operating distance Sao | |
Contact status indication with LED | min.7 mm |
With center offset m=0 | min.9 mm |