Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 085617 ESM-TE301

Euchner ESM-TE301 085617

 ESM-TE301 Euchner 085617
Manufacturer
Euchner
Name
ESM-TE301
Part number
085617
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 085617 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 085617 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 085617 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 085617 spares for all applications.

  • Swift Delivery: Quick access to Euchner 085617 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 085617 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 085617 Industrial components.

Order Euchner 085617 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications ESM-TE301 085617

  • Usage up to category 3 according to EN ISO 13849-1
  • LED status indicators
  • Control using safety relays
  • 3 redundant time-delayed safety contacts
  • Delay time-range 1 s - 30 s
  • 1 auxiliary contact
  • Earth fault/ground fault monitoring can be selected
Relay outputsThe outputs are electrically decoupled and of redundant design. ConnectionBy using suitable wiring the following function can be selected:
  • Earth fault/ground fault monitoring to detect short circuits between the connection cables and earth or ground and to shut down the outputs or prevent relay starting if necessary.
Time-delayed shutdownThe release time for the time-delay contacts can be set as required using a potentiometer on the safety relay. Dimension drawing Wiring diagram Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,23 kg
Ambient temperature
At UB = 24V AC -15 ... 40 °C
At UB = 24V DC -15 ... 60 °C
Degree of protection IP20
Mechanical life
operating cycles 10 x 106
Contact material AgNi-10
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Length of control cable
With conductor cross-section 0.75mm2 1000 m
Safety contacts 17/18, 27/28, 37/38
Number of safety contacts 3
Auxiliary contacts S25/S26
Number of auxiliary contacts 1
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10%
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp
Leakage path/air gaps 4 kV
Overvoltage category according to IEC EN 60664-1 3
Reverse polarity protection
On version UB =24V DC
Power consumption
at 24V DC 1,5 W
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm? Connection terminal (size)
Test voltage
Control system/contacts 2,5 kV
Control voltage
On S11 24 V
Control current
S11...S14 40 mA
LED indicator 2 status displays (green) for relays K1 and K2
Auxiliary contacts S25/S26
Type of output
NC As monitoring contact for safety relay
Switching characteristics Auxiliary contacts with adjustable time-delay
Safety contacts 17/18, 27/28, 37/38
Type of output
NO Relay contacts, positively driven (redundant)
Switching voltage
AC max.250 V
DC max.24 V
Switching current min.20 mA at 24V
Cumulative current max.10,5 A For all contacts
Fusing
External contact fuses (safety circuit) according to IEC 60269-1 10A gG (T4A / F6A)
Utilization category according to EN 60947-5-1
AC-15 4A, 250V
DC-13 2A, 24V
AC-12 6A ohmic load, 250V
DC-12 1.25A ohmic load, 24V
Breaking capacity according to UL 6A 250V AC / 2A 24V DC per contact
Switching characteristics Safety contacts with adjustable time-delay
Delay time
Continuously adjustable 1 ... 30 s
Other
In compliance with EN 60439-1: 1999 + A1: 2004, EN 60947-1: 2007, EN 60947-5-1: 2004, EN 60947-7-1: 2002, EN 61000-6-2: 2005, EN 61000-6-3: 2007, EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN 60204-1: 2007
Reliability values according to EN ISO 13849-1
Performance Level PL d
Category 3
PFHD 1.03 x 10-7
Number of switching cycles
? 1 A at 24V DC max.73000 1/Jahr
? 3 A at 24V DC max.17000 1/Jahr
? 0.1 A at 24 V DC max.400000 1/Jahr
Mission time 20 y