Supply of spare parts for industrial enterprises around the world
Home Brands Pepperl+Fuchs 233601 KCD0-SD-EX1.1245

Pepperl+Fuchs KCD0-SD-EX1.1245 233601

Solenoid Driver KCD0-SD-EX1.1245 Pepperl+Fuchs 233601
Manufacturer
Pepperl+Fuchs
Name
KCD0-SD-EX1.1245
Part number
233601
Country
Germany
Type
Solenoid Driver
Weight (g)
100
Sale of any product from the Pepperl+Fuchs catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Pepperl+Fuchs (official website: www.pepperl-fuchs.com). We sell only certified goods and give an official guarantee from the manufacturer Pepperl+Fuchs


This isolated barrier is used for intrinsic safety applications. The device supplies power to solenoids, LEDs and audible alarms located in a hazardous area. The device is loop powered, so the available energy at the output is received from the input signal. The output signal has a resistive characteristic. As a result the output voltage and current are dependent on the load and the input voltage At full load, 12 V at 45 mA is available for the hazardous area application.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications KCD0-SD-EX1.1245 233601

Product Description
current limit 45 mA
General specifications
Signal typeDigital Output
Functional safety related parameters
Safety Integrity Level (SIL)SIL 3
Supply
Rated voltageloop powered
Power dissipation< 1 W
Input
Connection sidecontrol side
Connectionterminals 5, 6
Rated voltage19 ... 30 V DC
Current&le, 72 mA at Ui = 19 V, &le, 50 mA at Ui = 30 V with 265 &Omega, output load &le, 45 mA at Ui = 19 V, &le, 31 mA at Ui = 30 V with shorted output &le, 14 mA at Ui = 19 V, &le, 11 mA at Ui = 30 V no load at output
Inrush current&le, 200 mA after 100 µ,s
Output
Connection sidefield side
Connectionterminals 1+, 2-
Internal resistormax. 238 &Omega,
Current&le, 45 mA
Voltage&ge, 12 V
Open loop voltagemin. 22.7 V
Output rated operating current45 mA
Output signalThese values are valid for the rated operating voltage 19 ... 30 V DC.
Energized/De-energized delaysingle operation: typ. 1.7 ms/50 µ,s, periodical: typ. 5 µ,s/50 µ,s
Galvanic isolation
Input/Outputreinforced insulation acc. to EN 50178, rated insulation voltage 300 Veff
Indicators/settings
Display elementsLED
Labelingspace for labeling at the front
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Conformity
Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Protection against electrical shockUL 61010-1
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protectionIP20
Connectionscrew terminals
Massapprox. 100 g
Dimensions12.5 x 114 x 119 mm (0.5 x 4.5 x 4.7 inch) , housing type A2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-Type Examination CertificateBASEEFA 06 ATEX 0170
Marking II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I
Output[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Voltage25.2 V
Current110 mA
Power693 mW
Input
Maximum safe voltage250 V (Attention! The rated voltage can be lower.)
CertificatePF 06 CERT 0971 X
Marking II 3G Ex nA IIC T4 Gc
Galvanic isolation
Input/Outputsafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity
Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
International approvals
FM approval
Control drawing116-0419 (cFMus)
UL approval
Control drawing116-0420 (cULus)
IECEx approvalIECEx BAS 06.0032
Approved for[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
General information
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.