Supply of spare parts for industrial enterprises around the world
Home Brands Pepperl+Fuchs 229182 VAA-2E1A-G10-SAJ/EA2J-1M

Pepperl+Fuchs VAA-2E1A-G10-SAJ/EA2J-1M 229182

Safety switch VAA-2E1A-G10-SAJ/EA2J-1M Pepperl+Fuchs 229182
Manufacturer
Pepperl+Fuchs
Name
VAA-2E1A-G10-SAJ/EA2J-1M
Part number
229182
Country
Germany
Type
Safety switch
Weight (g)
150
Sale of any product from the Pepperl+Fuchs catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Pepperl+Fuchs (official website: www.pepperl-fuchs.com). We sell only certified goods and give an official guarantee from the manufacturer Pepperl+Fuchs


The VAA-2E1A-G10-SAJ/EA2J- * is an AS-Interface safety module with 2 safety-related inputs and one conventional output. A two-channel mechanical switch or a single channel mechanical switch each can be connected to the two safety-related inputs. The output is a conventional electronic non-safety-related output, which can be loaded with 50 mA. The module is suitable for remote connection of switches in very limited space. The onepiece housing provides a degree of protection of IP67. The connection to the AS-Interface cable is achieved by means of insulation piercing method of the inserted flat cables. The inputs and the output are connected via open cable ends. To display the current switching state, there is a LED for each channel mounted on top of the module. A LED indicating the AS-Interface communication and the adress 0 of the module is also available. If a communication error occurs, the outputs are switched off (only at P0 = 1). The module can be used up to Category 4/PL e according to ISO 13849-1, SIL 3 according to EN 62061. If two single-channel switches are connected, the module can be used up to Category 2/ PL c according to ISO 13849-1, SIL 1 according to EN 62061.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications VAA-2E1A-G10-SAJ/EA2J-1M 229182

Product Description
G10 safety module 2 safety inputs and 1 standard electronic output
General specifications
Slave typeSafety-Slave
AS-Interface specificationV3.0
Required master specification&ge, V2.1
UL File NumberE223772 For use in NFPA 79 Applications only
Indicators/operating means
LED FLTerror display, LED red red: communication error or address is 0
LED AS-iAS-Interface voltage, green LED green: voltage OK flashing green: address 0
LED INswitching state (input), 2 LED yellow
LED OUTSwitching state (output), LED yellow
Electrical specifications
Rated operating voltage26.5 ... 31.6 V from AS-Interface (PELV)
Rated operating current&le, 90 mA
Protection classIII
Surge protectionovervoltage category III
Rated insulation voltage32 V
Pulse withstand voltage0.8 kV
Input
Number/Type2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or 1 2-channel contact: up to category 4/PL e to ISO 13849-1
Supplyfrom AS-Interface
Voltage20 ... 30 V DC pulsed
Currentinput current limited &le, 15 mA, short-circuit protected
Output
Number/Type1 conventional electronic output, PNP
Supplyfrom AS-Interface
Voltage(UASI - 7.0 V) &le, UOUT &le, UASI
Current50 mA , short-circuit/overload protected
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007
Machinery Directive
Directive 2006/42/ECEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
Electrical safetyIEC 61140:2009
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityIEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005
Functional safetyEN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015
Programming instructions
ProfileS-7.B
IO code7
ID codeB
ID1 codeF
ID2 code0
Data bits (function via AS-Interface) input output
D0 dyn. safety code 1 OUT 1
D1 dyn. safety code 1 -
D2 dyn. safety code 2 -
D3 dyn. safety code 2 -
Parameter bits (programmable via AS-i)function
P0communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition
P1not used
P2not used
P3not used
Approvals and certificates
UL approvalcULus Listed, Type 1 enclosure
Ambient conditions
Ambient temperature-20 ... 60 °C (-4 ... 140 °F)
Storage temperature-25 ... 80 °C (-13 ... 176 °F)
Relative humidity< 95 %
Altitude&le, 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3
Mechanical specifications
Degree of protectionIP67 This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE
ConnectionAS-Interface: AS-Interface flat cable Inputs/outputs: open conductor ends
Material
Contactsopen conductor ends with connector sleeves
HousingPBT
CablePUR
Mounting screwStainless steel 1.4305 / AISI 303
Cable
Sheath diameter&empty,4.8 mm
Bending radius> 8 x cable diameter, fixed > 10 x cable diameter, moving not appropriate for conveyor chains
Colorblack
Cores6 x 0.25 mm2
Length1 m
Mass200 g
Tightening torque, fastening screws1.65 Nm