General specifications |
Sensing range | 200 ... 4000 mm |
Adjustment range | 240 ... 4000 mm |
Dead band | 0 ... 200 mm |
Standard target plate | 100 mm x 100 mm |
Transducer frequency | approx. 85 kHz |
Response delay | minimum : 115 ms
factory setting: 225 ms |
Indicators/operating means |
LED green | solid: Power on
flashing: Standby mode or IO link communication |
LED yellow 1 | solid: Object in evaluation range
flashing: Learning function, object detected |
LED yellow 2 | solid: Object in evaluation range
flashing: Learning function, object detected |
LED red | solid red: Error
red, flashing: program function, object not detected |
Electrical specifications |
Operating voltage | 10 ... 30 V DC , ripple 10 %SS
15 ... 30 V voltage output |
No-load supply current | &le, 60 mA |
Power consumption | &le, 1 W |
Interface |
Interface type | IO-Link |
Protocol | IO-Link V1.0 |
Transfer rate | Acyclical: typical 54 Bit/s |
Cycle time | min. 59.2 ms |
Process data width | 16 bit |
SIO mode support | yes |
Input/Output |
Input/output type | 1 synchronization connection, bidirectional |
| 0 Level | 0 ... 1 V |
| 1 Level | 4 V ... UB |
| Input impedance | > 12 k&Omega, |
| Output rated operating current | < 12 mA |
| Pulse length | 0.5 ... 300 ms (level 1) |
| Pulse interval | &ge, 62 ms (level 0) |
Synchronization frequency | |
| Common mode operation | &le, 16 Hz |
| Multiplex operation | &le, 17 Hz / n , n = number of sensors , n &le, 10
(factory setting: n = 5 ) |
Output |
Output type | 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected
Current output 4 mA ... 20 mA or
voltage output 0 V ... 10 V configurable |
Rated operating current | 200 mA , short-circuit/overload protected |
Voltage drop | &le, 2.5 V |
Resolution | current output: evaluation range [mm]/3200 but &ge, 0.35 mm
voltage output: evaluation range [mm]/4000 but &ge, 0.35 mm
|
Deviation of the characteristic curve | &le, 0.2 % of full-scale value |
Repeat accuracy | &le, 0.1 % of full-scale value |
Switching frequency | &le, 2 Hz |
Range hysteresis | 1 % of the adjusted operating range (default settings), programmable |
Load impedance | current output: &le, 300 Ohm
voltage output: &ge, 1000 Ohm |
Temperature influence | &le, 1.5 % from full-scale value (with temperature compensation)
&le, 0.2 %/K (without temperature compensation) |
Approvals and certificates |
UL approval | cULus Listed, General Purpose |
CSA approval | cCSAus Listed, General Purpose |
CCC approval | CCC approval / marking not required for products rated &le,36 V |
Ambient conditions |
Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
Mechanical specifications |
Connection type | Connector plug M12 x 1 , 5-pin |
Degree of protection | IP67 |
Material | |
| Housing | Stainless steel 1.4305 / AISI 303
TPU
Polyamides |
| Transducer | epoxy resin/hollow glass sphere mixture, polyurethane foam |
Mass | 95 g |