Supply of spare parts for industrial enterprises around the world
Home Brands Pepperl+Fuchs 186880 VAA-4E4A-KE1-Z/E2

Pepperl+Fuchs VAA-4E4A-KE1-Z/E2 186880

Module VAA-4E4A-KE1-Z/E2 Pepperl+Fuchs 186880
Manufacturer
Pepperl+Fuchs
Name
VAA-4E4A-KE1-Z/E2
Part number
186880
Country
Germany
Type
Module
Weight (g)
115
Sale of any product from the Pepperl+Fuchs catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Pepperl+Fuchs (official website: www.pepperl-fuchs.com). We sell only certified goods and give an official guarantee from the manufacturer Pepperl+Fuchs


The AS-Interface Module VAA-4E4A-KE1-Z/E2 is a control cabinet with 4 inputs and 4 electronic outputs. The housing, only 22.5 mm in width and 48.5 mm in height, takes up little place in the switch cabinet. The module features an integrated addressing jack is mounted by snapping onto the 35 mm DIN rail in accordance with EN 50022. For easy disconnection for commissioning and servicing, the connection is via plug-in black 4-pin spring terminals. The external auxiliary voltage, the AS-Interface cable, the inputs and outputs (IN and O), as well as the plus potential of the inputs (I+) and the minus potential of the outputs (O-) are connected with the module via double terminals. The inputs and outputs and the connected sensors and actuators are supplied via external auxiliary power UAUX. Polarity reversal is signalled by a red light on the AUX-LED. The current switching status is indicated for each input and output by means of an LED on the top of the module. Note: The device features communication monitoring. It switches off the power to the outputs when no communication has occurred on the AS-Interface cable for more than 40 ms. In the event of overloading of the outputs, e.g. due to short-circuiting, the FAULT-LED on the module flashes and a signal is communicated to the AS-Interface master via the Peripheral error function. Communication via the AS-Interface remains uninterrupted.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications VAA-4E4A-KE1-Z/E2 186880

Product Description
KE1 switch cabinet module 4 inputs and 4 outputs
General specifications
Slave typeStandard slave
AS-Interface specificationV3.0
Required master specification&ge, V2.0
UL File NumberE87056
Functional safety related parameters
MTTFd90 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
LED FAULTerror display, LED red red: communication error or address is 0 red flashing: overload of outputs
LED PWRAS-Interface voltage, LED green
LED AUXext. auxiliary voltage UAUX, dual LED green/red green: voltage OK red: reverse voltage
LED INswitching state (input), 4 LED yellow
LED OUTSwitching state (output), 4 LED yellow
Electrical specifications
Auxiliary voltage (output)20 ... 30 V DC PELV
Rated operating voltage26.5 ... 31.6 V from AS-Interface
Rated operating current&le, 40 mA
Protection classIII
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV)
Input
Number/Type4 inputs for 2-wire sensors (PNP), DC or for mechanical contacts
Supplyfrom external auxiliary voltage UAUX
Input current&le, 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)&le, 2 mA
1 (attenuated)&ge, 4 mA
Signal delay< 2 ms (input/AS-Interface)
Signal frequency&le, 250 Hz
Output
Number/Type4 electronic outputs, PNP, overload and short-circuit proof
Supplyfrom external auxiliary voltage UAUX
Current0.5 A per output , 2 A per module
Voltage&ge, (UAUX - 0.5 V)
Usage categoryDC-13
Directive conformity
Electromagnetic compatibility
Directive 2014/30/EUIEC 62026-2:2015 EN 61326-1:2006
Standard conformity
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2015
Emitted interferenceEN 55011:2009
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61326-1:2006
Programming instructions
ProfileS-7.0
IO code7
ID code0
ID1 codeF
ID2 codeE
Data bits (function via AS-Interface) input output
D0 IN1 O1
D1 IN2 O2
D2 IN3 O3
D3 IN4 O4
Parameter bits (programmable via AS-i)function
P0Communication monitoring P0 = 0 monitoring = off, the outputs maintain the status if communication fails P0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings)
P1Input filter P1 = 0 input filter on, pulse suppression &le, 2 ms P1 = 1 input filter off (default settings)
P2Synchronous mode P2 = 0 synchronous mode on P2 = 1 synchronous mode off (default settings)
P3not used
Ambient conditions
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity90 % , noncondensing
Pollution degree2
Mechanical specifications
Degree of protectionIP20
Connectionremovable spring double terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2 recommended tools for 1.5 mm2: PxC CRIMPFOX ZA3 or Weidmüller PZ 6 roto
Material
HousingPA 66-FR
Mass80 g
MountingDIN mounting rail