General specifications |
Measuring method | The tuning fork is brought to its resonance frequency by means of a piezoelectric drive. If the tuning fork is covered by liquid, this frequency changes. The electronics monitor the resonance frequency and indicate whether the tuning fork is freely vibrating or is covered by liquid. |
Construction type | compact device
device with short tube |
Operating mode | MAX = maximum safety:
The device keeps the electronic switch closed as long as the liquid level is below the fork.
example application: overspill protection
MIN = minimum safety:
The device keeps the electronic switch closed as long as the fork is immersed in liquid.
example application: dry running protection of pumps
The electronic switch opens if the limit is reached, if a fault occurs or in the event of a power fails (quiescent current principle) |
Supply |
Rated voltage | - DC-PNP: 10 ... 35 V DC, 3-wire
- AC/DC: 20 ... 253 V AC/DC, 2-wire |
Current consumption | - DC-PNP: < 15 mA
- AC/DC: < 3.8 mA |
Power consumption | - DC-PNP: < 975 mW
- AC/DC: < 850 mW |
Input |
Measured variable | density |
Measurement range | min. 0.7 g/cm3, optional> 0.5 g/cm3 |
Output |
Output type | switch output |
Switching current | max. 250 mA |
Directive conformity |
Electromagnetic compatibility | |
| Directive 2014/30/EU | EN 61326-1:2006 , EN 61326-2-3:2006 |
Low voltage | |
| Directive 2014/35/EU | EN 61010-1:2010 |
Conformity |
Electromagnetic compatibility | NE 21 |
Degree of protection | IEC 60529 |
Shock resistance | EN 60068-2-27 |
Vibration resistance | EN 60068-2-64 |
Climate class | DIN EN 60068-2-38/IEC 68-2-38 |
Measurement accuracy |
Reference operating conditions | - ambient temperature: 25 °C (+77 °F)
- process pressure: 1 bar (14.5 psi)
- fluid: water (density: approx. 1 g/cm3, viscosity: 1 mm2/s)
- medium temperature: 25 °C (+77 °F)
- density setting: > 0.7 g/cm3
- switching time delay: standard (0,5 s, 1 s) |
Measured value resolution | < 0.5 mm |
Measuring frequency | approx. 1100 Hz in air |
Switching point | 13 mm ± 1 mm |
Non-repeatability | ± 1 mm acc. to DIN 61298-2 |
Hysteresis | max. 3 mm |
Influence of ambient temperature | negligible |
Influence of medium temperature | -25 µ,m/°C |
Influence of medium pressure | -20 µ,m/bar |
Switching time | - 0.5 s when tuning fork is covered
- 1.0 s when tuning fork is uncovered
- other switching times on request |
Operating conditions |
Installation conditions | |
| Installation position | see section mounting position |
Ambient conditions | |
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Shock resistance | a = 300 m/s2 = 30 g, 3 planes x 2 directions x 3 shocks x 18 ms, as per test Ea |
| Vibration resistance | a(RMS) = 50 m/s2, ASD = 1.25 (m/s2)2/Hz, f = 5 to 2000 Hz, t = 3 x 2 h |
Process conditions | |
| Medium temperature | -40 ... +100 °C (-40 ... +212 °F)
-40 ... +150 °C (-40 ... +302 °F) |
| Process pressure (static pressure) | -1 ... +40 bar (-14.5 ... +580 psi) |
| State of aggregation | liquid |
| Density | min. 0.7 g/cm3, optional> 0.5 g/cm3 |
| Viscosity | 1 ... 10000 mPa/s, dynamic viscosity |
| Solid contents | < &empty,5 mm |
Mechanical specifications |
Degree of protection | - IP65/67, NEMA 4X enclosure (plug M12)
- IP65, NEMA 4X enclosure (valve plug)
- IP65/68, NEMA 4X/6P enclosure (cable) |
Connection | - cable 5 m
- valve plug NPT1/2
- valve plug QUICKON
- valve plug M16
- plug M12 |
Material | see technical information (TI) |
Surface quality | Ra < 3.2 µ,m |
Mass | see technical information (TI) |
Dimensions | see technical information (TI) |
Process connection | - thread ISO 228 G1/2, G3/4, G1
- thread EN 10226 R1/2, R3/4, R1
- thread ASME MNPT1/2, MNPT3/4, MNPT1 |
Indication and operation |
Display elements | The LED display is on the connection side.
- green LED: indication of ready to operate
- red LED: fault indication
- yellow LED: operating mode indication |
Function test | function test with test magnet (optional accessory) |
Certificates and approvals |
Overspill protection | Z-65.11-554 (overspill protection acc. to WHG)
Z-65.40-555 (leak detection system acc. to WHG)
If you need the approvals also in paper form, select the option WH in the type code. |
General information |
Supplementary documentation | technical information (TI)
manual (BA)
approval (ZE) |
Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Accessories |
Designation | see technical information (TI) |