Application |
---|
Measuring element | 1 x Pt 1000, (to DIN EN 60751 class A) |
Media | Liquid or gaseous media |
Pressure strength [bar] | 160 |
Vacuum resistance [mbar] | -1000 |
MAWP ( for use according to CRN) [bar] | 160 |
Electronic data |
---|
Operating voltage [V] | 18…32 DC, ("power class 2" according to cULus) |
Current consumption [mA] | <50 |
Protection class | III |
Reverse polarity protection | yes |
Power supply delay time [s] | 2 |
Inputs/outputs |
---|
Number of industrial outputs | Number of industrial outputs: 1 |
Outputs |
Total number of outputs | 1 |
Output signal | Analog signal, IO-Link, (adjustable adjustable) |
Number of industrial outputs | 1 |
Analog current output [mA] td> | 4…20 |
Maximum load [?] | 250, ((18…19 V), 19…32 V: 300? ) |
Short circuit protection | Yes |
Overcurrent protection | yes |
Measuring/building range |
---|
Measuring range [°C] | - 50…200 |
Factory setting | -10…150 °C |
Resolution |
---|
Production output resolution [K] | 0.04 |
Precision/Uncertainty |
---|
Production yield accuracy [K] | ± 0.3 + (± 0.1 % MS) |
Temperature coefficient [% of the beginning of the measurement / 10 K] | 0.1, (When deviating from ambient conditions 25 ± 5 °C) |
Time response |
---|
Dynamics of response T05 / T09 [s] | <0.5 / <2 |
Interfaces |
---|
Communication interface | IO-Link |
Transmission method | COM2 (38.4 kbaud) |
IO-Link test | 1.1 |
Conditions operation |
---|
Ambient temperature [°C]-25…80 |
Ambient temperature note | at medium temperature: <160 °C | -25…60 °C | at medium temperature: <200 °C |
|
Storage temperature [°C] | -40…100 |
Degree of protection | IP 67, IP 68, IP 69K |
Tests / approvals |
---|
EMC | DIN EN 61000-6-2 | | DIN EN 61000-6-3 | |
|
Impact resistance | DIN IEC 68-2 -27 | 50 g (11 ms) |
|
Vibration resistance | DIN IEC 68-2-6 | 10 g (10…2000 Hz) |
|
MTTF [years] | 334 |
UL certified | UL registration number | K002 |
|
Mechanical data |
---|
Weight [g] | 181.5 |
Dimensions [mm] | O 18.7 |
Material | stainless steel steel (1.4404 / 316L), PEI, FKM medium | stainless steel steel (1.4404 / 316L) electropolished |
Process connection | G 1/2 threaded connection Cone seal |
Surface characteristic Ra/Rz of the parts in contact with the medium | Ra: <0.8 |
Probe diameter [mm] | 6 |
Installation length EL [mm] | 50 |
Notes |
---|
Notes | MS = measuring interval setting | Values accuracy refer to running water. |
|
Packing quantity | 1 piece td> |
Electrical connection |
---|
Connection | Connector: 1 x M12 |