Application |
---|
Application | hygienic systems |
Medium | Liquid or gaseous media |
Regularly suitable for | Application in gaseous media is limited to 25 bar. |
td> |
Measured medium temperature [°C] | -25…100, (145 max 1h) |
Tensile strength [bar] | 800 |
Min. burst pressure [bar] | 1200 |
Type of pressure | relative pressure |
Electronic data |
---|
Operating voltage [V] | 20…30 DC |
Current consumption [mA] | < 65 |
Min. insulation resistance [M?] | 100, (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Power-on delay time [s] | 0.3 |
Built-in watchdog | yes |
Inputs/outputs |
---|
Number of inputs and outputs | Number of digital outputs: 2, Number of analog outputs: 1 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | Switching signal, analog signal, (configurable ) |
Electrical version | PNP/NPN |
Number of digital outputs | 2 |
Output function | normally open / normally closed, (parameterizable) |
Max . voltage drop DC switching output [V] | 2 |
DC switching output load current [mA] | 250 |
DC switching frequency [Hz] | < 170 |
Number of analog outputs | 1 |
Analog current output [mA] | 4…20, (scaled 1:4) |
Maximum load [?] | (Ub - 10 V) / 20 mA |
Analog voltage output [V] | 0…10, (scaled 1:4) |
Min. load resistance [?] | 2000 |
Short circuit protection | yes |
Type of short-circuit protection | clocked |
Overcurrent protection | yes |
Measuring/setting range |
---|
Measuring range [bar] | 0…600 |
Setting point SP [bar] | 6…600 |
Reset point rP [bar] | 3…597 |
Analog start point [bar] | 0…240 |
Analog end point [bar] | 150…600 |
In increments of [bar] | 3 |
Accuracy/accuracy |
---|
Switch point error [% of range] | < ± 1.0, (Turn down 1:1) |
Repeatability [% of range] | < ± 0.25, (at temperature changes < 10 K, Turn down 1:1) |
Deviation of characteristic [% of span] | < ± 1.0, (Turn down 1:1 linearity incl. hysteresis and repeatability of settings and limit value according to DIN 16086) |
Linearity deviation [% of span] | < ± 0.5, (Turn down 1:1) |
Hysteresis deviation [% of range] | < ± 1.0, (Turn down 1:1) |
Long-term stability [% of span] | < ± 0.25, (Turn down 1:1, per year) |
Zero point temperature coefficient [% of measuring range / 10 K] | < ± 0.2, (0...80 °C) |
Temperature coefficient of range [% of range measurement / 10 K] | < ± 0.2, (0...80 °C) |
Response time |
---|
Response time [ms] | < 3 |
Switching output damping dAP [s] | 0 …4 |
Analog output damping dAA in [s] steps | 0 - 0, 1 - 0, 5 - 2 |
Max. analog output response time [ms] | 3 |
Software / Programming |
---|
Parameter selection | hysteresis / window, normally open / normally closed, switching logic, current / voltage output, Damping, adaptation of displayed values, display can be rotated and switched off, Display, Zero point, span |
Operating conditions |
---|
Ambient temperature [°C] | -25…80 |
Storage temperature [°C] | -40…100 |
Degree of protection | IP 67 | td> |
Tests / Approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 RF emissions | 10 V/m | EN 61000-4-4 Burst | 2 kV 4-5 Surge | 0.5/1 kV | EN 61000-4-6 RF conductance | 10 V | td> |
|
Shock resistance | DIN EN 60068-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN EN 60068- 2-6 | 20 g (10…2000 Hz) |
|
MTTF [ years] | 145 |
Mechanical data |
---|
Weight [g] | 384 |
Material | stainless steel steel (1.4301/304), stainless steel steel (1.4404 / 316L), PC, PBT (polybutylene terephthalate), PA (polyamide), FKM, EPDM/X medium | stainless steel steel (1.4404 / 316L), ceramic (99.9% Al2 O3), FKM |
Min. pressure cycles | 50 million |
Process connection | Homogenizer connection |
Displays / Controls |
---|
Display | Display | 3 x LED, green | Output status | 2 x LED, yellow | Display functions | alphanumeric display, 4 digits | Measured values | alphanumeric display, 4 digits |
|
Display | bar, psi, MPa |
Notes |
---|
Packing quantity | 1 piece |
Electrical connection |
---|
Connection | Connector: 1 x M12, Contacts: gold-plated |