Application |
---|
Application | for mobile machinery |
MediumLiquid or gaseous media |
Measured medium temperature [°C] | -40…125 |
Pressure strength [bar] | 250 |
Note on pressure strength | |
Min. burst pressure [bar] | 1000 |
Vacuum resistance [mbar] | -1000 |
Pressure type | Relative pressure |
Electronic data |
---|
Operating voltage [ V] | 8…32 DC |
Min. insulation resistance [M?] | 100, (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Inputs/outputs |
---|
Number of inputs and outputs | Number of analog outputs: 1 |
Outputs |
---|
Total number of outputs | 1 |
Output signal | analog signal |
Number of analog outputs | Number of analog outputs | | 1 |
Analog current output [mA] | 4…20 |
Maximum load [?] | (Ub - 8 V) / 20 mA |
Short circuit protection | yes |
Overcurrent protection | yes |
Measuring/setting range |
---|
Measuring range [bar] | 0…100 |
Accuracy/inaccuracy |
---|
Repeatability [% of range] | < ± 0.05, (at temperature changes < 10 K) |
Deviation of characteristic [% of range ] | < ± 0.8, (incl. drift at tightening, zero point error and error, non-linearity, hysteresis) |
Linearity deviation [% span] | < ± 0.25 (BFSL) / < ± 0.5 (LS) |
Hysteresis deviation [% of span] | < ± 0.2 |
Long-term stability [% of span] | < ± 0.1, (over 6 months) |
Zero point temperature coefficient [% of span measurement / 10 K] | < ± 0.1 (0...80 °C), < ± 0.2 (-40...0 °C / 80...125 °C) |
Temperature coefficient range [% of measuring range / 10 K] | < ± 0.1 (0...80 °C), < ± 0.2 (-40...0 °C / 80...125 °C) |
Reaction time |
---|
Analog output transient rise time [ms] | 2 |
Operating conditions |
---|
Ambient temperature ambient temperature [°C] | -40…100 |
Storage temperature [°C] | -40…100 |
Degree of protection | IP 67, IP 69K |
Tests / approvals
EMC | Complies with UN ECE 10 rev. 4 | (meets requirements e1) | ISO 11452-2 | 100 V/m | DIN EN 61326-1 | |
|
Impact resistance | DIN EN 60068-2-27 | 500 g (1 ms) |
|
Vibration resistance | DIN EN 60068-2-6 | 20 g (10…2000 Hz)
|
MTTF [years] | 704 |
Pressure Equipment Directive | Good engineering practice, can be used for fluid group 2, fluid group 1 on request |
Mechanical data |
---|
Weight [g] | 58.5 |
Material | 1.4542 (17-4 PH / 630), stainless steel steel (1.4404 / 316L), PEI environment | 1.4542 (17-4 PH / 630) |
Min. pressure cycles | 60 million, (at 1.2 x rated pressure) |
Tightening torque [Nm] | 25…35, (recommended tightening torque, depending on lubrication, sealing and pressure rating) |
Process connection | G 1/4 male thread thread (DIN EN ISO 1179-2) |
Process seal | HNBR (according to DIN 3869) |
Built-in delimiter | yes |
Notes |
---|
Notes | BFSL = Best Fit Straight Line | LS = Set Limit |
|
Packing quantity | 1 piece |
electrical connection |
---|
Connection | Connector: 1 x M12, Maximum cable length: 30 m |
diagrams and graphics |
---|
current output load characteristic curve | 1: | Max load |
---|
2: | Max load load |
---|
|
---|