Application |
---|
Environment | Compressed air |
Conditionally suitable | other media on request |
Measured medium temperature [°C] | 0…60 |
Pressure strength [bar] | 20 |
Min. burst pressure [bar] | 30 |
Pressure type | relative pressure |
< th>Electronic data
Operating voltage [V] | 18…32 DC, (according to EN 50178 SELV/PELV) |
Current consumption [mA] | < 50 |
Min. insulation resistance [M?] | 100, (500 V DC) |
Protection class | III |
Reverse polarity protection | yes |
Overvoltage protection | yes, (< 40 V) |
Power-on delay time [s] | 0.3 |
Built-in Watchdog | yes |
Inputs/outputs |
---|
Number of inputs and outputs | Number digital outputs: 2 |
Outputs |
---|
Total number of outputs | 2 |
Output signal | Switching signal |
Electrical version | PNP |
Number of digital outputs | 2 |
Output signal function | normally open / normally closed, (parameterizable ) |
Max. voltage drop DC switching output [V] | 2 |
DC switching output load current [mA] | 100 |
Switching frequency DC [Hz] | < 200 |
Short circuit protection | yes |
Type of short-circuit protection | clocked |
Measurement/setting range |
---|
Measuring range [bar] | -1…10 |
Setting point SP [bar] | -0.9…10 |
Reset point rP [bar] | -0.95…9.95 |
In increments of [bar] | 0.05 |
Accuracy/Uncertainty |
---|
Switch point error [% of range] | < ± 0.5 |
Repeatability [% of range] | < ± 0.1, (at temperature changes < 10 K) |
Deviation from characteristic [% of span] | < ± 0.25 (BFSL ) / < ± 0.5 (LS), (BFSL = Best Fit Straight Line, LS = Set Limit) |
Hysteresis deviation [% of range] | < ± 0.25 |
Long-term stability [% of range] | < ± 0.05, (for 6 months) |
Zero point temperature coefficient [% of span / 10 K] | 0, 2, (0…60 °C) |
Temperature coefficient range [% of measuring range / 10 K] | 0.2, (0…60 °C) |
Response time |
---|
Response time [ms] | < 2.5 |
Programmable delay time dS, dr [s] | 0, 0.002…5 |
Software / Programming |
---|
Parameter selection | hysteresis / window, normally open / normally closed, diagnostic function, switching logic, on/off delay, damping, display |
Operating conditions |
---|
Ambient temperature [°C] | 0…70 |
Storage temperature [°C] | -25…85 |
Degree of protection | IP 65 |
Tests / approvals |
---|
EMC | EN 61000-4-2 ESD | 4 kV CD / 8 kV AD | EN 61000-4-3 RF emissions | | | 10 V/m | EN 61000-4-4 Burst | 2 kV | EN 61000-4-5 Surge | 0.5/1 kV | EN 61000-4-6 RF Conductivity | 10 V |
|
Impact resistance | DIN IEC 68-2-27 | 50 g (11 ms) |
|
Vibration resistance | DIN IEC 68-2-6 | 20 g (10…2000 Hz) |
|
MTTF [years] | 455 |
Mechanical data |
---|
Weight [g] | 84.5 |
Material | PBT (polybutylene terephthalate), FKM, polyester |
Body materials in contact with meas. medium | brass, FKM, silicon (lined), PBT (polybutylene terephthalate) |
Min. pressure cycles | 50 million |
Process connection | G 1/8 female thread |
Displays / Controls |
---|
Display | Display | 4 x LED, green | Output status | 2 x LED, yellow | Display functions | Alphanumeric display, 4-digit | Measured values | Alphanumeric display, 4- numeric |
|
Display | bar, kPa, psi, inHg |
Accessories |
---|
Accessories (optional) | mounting set for DIN rail: TH 35-7,5 / EN60715, E37340 | Fitting: 1/8?, E30075 | plug-in pipe fitting: Ø 6 mm, E30076 | plug-in pipe fitting: Ø 8 mm, E30077 |
|
Notes |
---|
Packing quantity | 1 piece |
Electrical connection |
---|
Connection | Connector: 1 x M8, Contacts: gold-plated |