Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 158763 CEM-A-LE05K-S2-P-158763

Euchner CEM-A-LE05K-S2-P-158763 158763

 CEM-A-LE05K-S2-P-158763 Euchner 158763
Manufacturer
Euchner
Name
CEM-A-LE05K-S2-P-158763
Part number
158763
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


CEM-A-LE05K-S2-P (158763)
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CEM-A-LE05K-S2-P-158763 158763

  • Read head with guard locking without guard lock monitoring
  • Locking force 650 N
  • With permanent magnet 30 N
  • Up to category 4 according to EN ISO 13849-1
  • Two safety screws M5x16 included
Approach direction Typical operating distance Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off.
Material
Read head Plastic (PPS)
Solenoid Steel, nickel-plated
Housing material Die-cast aluminum
Weight
Net 0,4 kg
Ambient temperature -25 ... 50 °C
Degree of protection IP67
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Switching frequency
Read head See operating instructions for the related evaluation unit
Solenoid max.1 Hz
Connection
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
X3, read head Plug connector M8x1, 3-pin male (with snap-action / screw terminal)
Cable length max.25 m
Guard locking principle Open-circuit current principle
Locking force F
(Not monitored, in axial direction) at UCM?24V 650 N
Adhesive force
by permanent magnet 30 N
Electrical connection ratings
Operating voltage DC
UCM 24 V DC -15% ... 10%
Current consumption
UB 100 mA
Power consumption 2,5 W
Solenoid duty cycle 100 %
Work area
Switching hysteresis 0,7 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao min.2 mm
Center offset -2,5 ... +2,5 mm