- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- With permanent magnet 30 N
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Approach direction Typical operating distance Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off.
Material | |
Read head | Plastic (PPS) |
Solenoid | Steel, nickel-plated |
Housing material | Die-cast aluminum |
Weight | |
Net | 0,4 kg |
Ambient temperature | -25 ... 50 °C |
Degree of protection | IP67 |
Mechanical life | |
In case of use as door stop, and 1 Joule impact energy | 1 x 106 |
Installation orientation | Any |
Switching frequency | |
Read head | See operating instructions for the related evaluation unit |
Solenoid | max.1 Hz |
Connection | |
X1, solenoid (yellow LED integrated in the plug) | Plug connector M8x1, 4-pin male (with snap-action / screw terminal) |
X3, read head | Plug connector M8x1, 3-pin male (with snap-action / screw terminal) |
Cable length | max.25 m |
Guard locking principle | Open-circuit current principle |
Locking force F | |
(Not monitored, in axial direction) at UCM?24V | 650 N |
Adhesive force | |
by permanent magnet | 30 N |
Electrical connection ratings
Operating voltage DC | |
UCM | 24 V DC -15% ... 10% |
Current consumption | |
UB | 100 mA |
Power consumption | 2,5 W |
Solenoid duty cycle | 100 % |
Work area
Switching hysteresis | 0,7 mm |
Assured switch-off distance Sar | max.20 mm |
Assured operating distance Sao | min.2 mm |
Center offset | -2,5 ... +2,5 mm |