Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 116505 CES-I-AP-U-C04-U20-116505

Euchner CES-I-AP-U-C04-U20-116505 116505

 CES-I-AP-U-C04-U20-116505 Euchner 116505
Manufacturer
Euchner
Name
CES-I-AP-U-C04-U20-116505
Part number
116505
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 116505 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 116505 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 116505 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 116505 spares for all applications.

  • Swift Delivery: Quick access to Euchner 116505 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 116505 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 116505 Industrial components.

Order Euchner 116505 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CES-I-AP-U-C04-U20-116505 116505

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Category 4/PL e according to EN ISO 13849-1
  • Three active faces
  • Connection cable PUR, 20 m, flying lead
  • Unicode
  • Monitoring output OD
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Terminal assignment
Designation Function Conductor coloring of connection cable
UB Power supply, DC 24 V BN
FO1A Safety output, channel 1 WH
0V Ground, DC 0 V BU
FO1B Safety output, channel 2 BK
OD Monitoring output GY
Material
Rubber support NBR 80 ±5 Shore
Housing material Plastic, PBT
Weight
Net 0,7 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -25 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.140 mm
Installation orientation Any
Tightening torque
Fixing screws max.0,8 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection connection cable PUR, length 20m
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV
Current consumption
No load on outputs max.35 mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 300 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Monitoring output OD
Type of output p-switching, short circuit-proof
Switching current max.50 mA
Output voltage 0,8 x UB ... UB V DC
Safety outputs FO1A / FO1B
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
LOW U(FO1A) / U(FO1B) 0 ... 1 V DC
HIGH U(FO1A) / U(FO1B) UB-1,5V ... UB V DC
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
Additional feature Rubber support included
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 4.1 x 10-9
Mission time 20
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance
Approach direction C or D (broad side) 11 mm
Approach direction A or B (front side) 15 mm
Assured operating distance Sao
Approach direction A or B (front side) min.10 mm
Approach direction C or D (broad side) min.6 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance
Approach direction C or D (broad side) 15 mm
Approach direction A or B (front side) 19 mm
Assured operating distance Sao
Approach direction A or B (front side) min.14 mm
Approach direction C or D (broad side) min.10 mm
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm