- Safety switch with integrated evaluation electronics
- No series connection
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Category 4/PL e according to EN ISO 13849-1
- Three active faces
- Connection cable PUR, 0.1 m, plug connector M12, 5-core, pin 5 not used
- Unicode
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (FO1A and FO1B) must be evaluated. LED indicator
STATE | Status LED |
DIA | Diagnostics LED |
Connector assignment
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connection cable |
| 1 | UB | Power supply, DC 24 V | BN |
2 | FO1A | Safety output, channel 1 | WH |
3 | 0V | Ground, DC 0 V | BU |
4 | FO1B | Safety output, channel 2 | BK |
5 | - | n.c. | GY |
Material | |
Rubber support | NBR 80 ±5 Shore |
Housing material | Plastic, PBT |
Weight | |
Net | 0,05 kg |
Ambient temperature | |
Cable dynamic | -25 ... 65 °C |
Cable static | -25 ... 65 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mounting method | Surface mounting on metal |
Mounting distance | |
Between 2 switches or 2 actuators | min.140 mm |
Installation orientation | Any |
Tightening torque | |
Fixing screws | max.0,8 Nm |
Ready delay | 0,5 s |
Switching frequency | max.1 Hz |
Connection | PUR cable 100mm with plug connector M12x1, 5-pin, pin 5 not used |
Bending radius | |
Dynamic | 10 x cable diameter |
static | 5 x cable diameter |
Electrical connection ratings
Operating voltage DC | |
UB | 24 V DC 15% ... 15% Regulated, residual ripple < 5%, PELV |
Current consumption | |
No load on outputs | max.35 mA |
Fusing | |
External (operating voltage) | 0,25 ... 8 A |
Rated insulation voltage Ui | 300 V |
Rated impulse withstand voltage Uimp | max.1,5 kV |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | max.300 ms |
Safety class | III |
Risk time according to EN 60947-5-3 | max.260 ms |
| Safety outputs FO1A / FO1B |
Test pulses | max.0,3 ms |
Test-pulse interval | min.100 ms |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
per safety output | 1 ... 150 mA |
Output voltage | |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
HIGH U(FO1A) / U(FO1B) | UB-1,5V ... UB V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Rated conditional short-circuit current | 100 A |
Off-state current Ir | max.0,25 mA |
Discrepancy time | max.10 ms |
Work area
Other
Additional feature | Rubber support included |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures |
Reliability values according to EN ISO 13849-1
| Monitoring of the safety guard position |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-9 |
Mission time | 20 |
In combination with Actuator CES-A-BBN-C04-115271Operating distance
Switch-on distance | |
Approach direction C or D (broad side) | 11 mm |
Approach direction A or B (front side) | 15 mm |
Assured operating distance Sao | |
Approach direction A or B (front side) | min.10 mm |
Approach direction C or D (broad side) | min.6 mm |
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance | |
Approach direction A or B (front side) | 19 mm |
Approach direction C or D (broad side) | 15 mm |
Assured operating distance Sao | |
Approach direction C or D (broad side) | min.10 mm |
Approach direction A or B (front side) | min.14 mm |
In combination with Actuator CES-A-BDN-06-104730, CES-A-BBN-C04-115271Operating distance
Assured switch-off distance Sar | |
In y direction | max.60 mm |
In x/z direction | max.40 mm |
Switching hysteresis | min.1 mm |