- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Indication of the door position by LED
- Approach direction A (default setting on delivery)
Approach direction Horizontal Can be adjusted in 90° steps Safety switch The device may be operated only in conjunction with the actuator CET-A-.... Important: The actuator must be ordered separately. Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected. Solenoid operating voltage
Guard locking type
CET3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
LED function display
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | illuminates when the solenoid is energized |
LED 2 gn | illuminates when door is closed |
Category according to EN ISO 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
- Category 4/PL e according to EN ISO 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. The category is dependent on the installation position of the safety switch: Connector assignment
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
| X 1.1 | UB | Operating voltage 24 V DC | BN |
X 1.2 | OA | Safety output, channel 1 | WH |
X 1.3 | 0V | Operating voltage 0 V | BU |
X 1.4 | OB | Safety output, channel 2 | BK |
X 1.5 | - | n.c. | GY |
| | | |
X 2.1 | - | n.c. | BN |
X 2.2 | - | n.c. | WH |
X 2.3 | 0VUCM | 0V solenoid | BU |
X 2.4 | UCM | Operating voltage of guard locking solenoid 24 V DC | BK |
X 2.5 | - | n.c. | GY |
Dimension drawing Block diagram Wiring diagram CET: Transponder-coded safety switch with guard locking CET3-AP: Mounting and Setup CET3-AP (closed-circuit current principle) CET3-AP: Mounting auxiliary release with key CET3-AP CET3-AP: Mounting emergency release safety swith CET3-AP Dimension drawingBlock diagramWiring diagram Technical dataApprovals Mechanical values and environment
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Electrical connection ratings
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
| Safety outputs OA/OB |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Work area
Other
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
Category | |
Head upward | 3 |
Head downward or horizontal | 4 |
Performance Level | PL e |
PFHD | |
Head downward or horizontal | 3.1 x 10-9 |
Head upward | 4.29 x 10-8 |
| Control of the guard locking |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |