Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 109168 CES-AP-CR2-CH-SB-109168

Euchner CES-AP-CR2-CH-SB-109168 109168

 CES-AP-CR2-CH-SB-109168 Euchner 109168
Manufacturer
Euchner
Name
CES-AP-CR2-CH-SB-109168
Part number
109168
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 109168 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 109168 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 109168 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 109168 spares for all applications.

  • Swift Delivery: Quick access to Euchner 109168 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 109168 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 109168 Industrial components.

Order Euchner 109168 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CES-AP-CR2-CH-SB-109168 109168

  • Safety switch with integrated evaluation electronics
  • No series connection
  • Short circuit monitoring
  • 2 safety outputs (semiconductor outputs)
  • Door hinge right
  • Category 4/PL e according to EN ISO 13849-1
  • Connection cable PUR, 0.2 m, plug connector M12, 5-core, pin 5 not used
  • Multicode
  • Two safety screws M4x14 included
Short circuit monitoring The switch generates its own clock signal on the output cables OA/OB. Pay attention to this aspect when connecting to control systems and relays. Multicode evaluation Every suitable actuator is detected by the switch. Category according to EN 13849-1 Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
  • Category 4/PL e according to EN 13849-1
Important: To achieve the stated category in accordance with EN ISO 13849-1, both safety outputs (OA and OB) must be evaluated. LED indicator
STATEStatus LED
DIADiagnostics LED
Approach directions Typical operating distance (Actuator CES-A-BLN... in conjunction with safety switch CES-AP-C.2-... in case of mounting on plastic) For a side approach direction for the actuator and safety switch, a minimum distance of s = 6 mm must be maintained so that the operating distance of the side lobes is not entered. Attention: The operating distance may vary depending on the background material and installation situation. Connector assignment
Plug connector (view of connection side) Pin Designation Function Conductor coloring of connection cable
1 UB Power supply, DC 24 V BN
2 OA Safety output, channel 1 WH
3 0V Ground, DC 0 V BU
4 OB Safety output, channel 2 BK
5 - n.c. GY
Housing material Plastic, PBT
Weight
Net 0,06 kg
Ambient temperature
Cable static -25 ... 65 °C
Cable dynamic -5 ... 65 °C
Degree of protection IP67
Resilience to vibration In acc. with EN IEC 60947-5-2
Mounting method Surface mounting on metal
Mounting distance
Between 2 switches or 2 actuators min.400 mm
Installation orientation Any
Tightening torque
Fixing screws max.1 Nm
Ready delay 0,5 s
Switching frequency max.1 Hz
Connection Connection cable PUR 0.2m with plug connector M12 5-pin, pin 5 not used
Bending radius
static 5 x cable diameter
Dynamic 10 x cable diameter
Electrical connection ratings
Operating voltage DC
UB 24 V DC 15% ... 15% Regulated, residual ripple < 5 %
Current consumption max.30 mA
Utilization category according to EN 60947-5-2
DC-13 24V 150mA
Fusing
External (operating voltage) 0,25 ... 8 A
Rated insulation voltage Ui 75 V
Rated impulse withstand voltage Uimp max.1,5 kV
EMC protection requirements In acc. with EN IEC 60947-5-3
Degree of contamination (external, according to EN 60947-1) 3
Switch-on time
Safety outputs max.300 ms
Safety class III
Risk time according to EN 60947-5-3 max.260 ms
Safety outputs OA/OB
Test pulses max.0,3 ms
Test-pulse interval min.100 ms
Type of output Semiconductor outputs, p-switching, short circuit-proof
Switching current
per safety output 1 ... 150 mA
Output voltage
LOW U(OA) / U(OB) 0 ... 1 V DC
HIGH U(OA) / U(OB) UB-1,5V ... UB V DC
Rated conditional short-circuit current 100 A
Off-state current Ir max.0,25 mA
Discrepancy time max.10 ms
Work area
Repeat accuracy R ? 10
Other
For the approval according to UL the following applies Operation only with UL class 2 power supply, or equivalent measures
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category 4
Performance Level PL e
PFHD 1.8 x 10-9
Mission time 20
In combination with Actuator CES-A-BLN-R2-100776, CES-A-BLN-U2-103450, CES-A-BLN-L2-104510, CES-A-BLN-U2-112710Operating distance
Switch-on distance 15 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.10 mm
Switching hysteresis min.1 mm
In combination with Actuator CES-A-BDN-06-104730Operating distance
Switch-on distance 19 mm
Assured switch-off distance Sar
In y direction max.60 mm
In x/z direction max.40 mm
Assured operating distance Sao min.14 mm
Switching hysteresis min.1 mm