- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 8 pushbuttons illuminated
- Operating mode selector switch
- 1 indicator
- Including adhesive labels
- Push-pull plug
- Including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- With escape release
- Multicode
Profinet connection Connection via push-pull plugs according to IEC 61076-3-117 Profinet RT switch Point-to-point topology network structure due to integrated RT switch. Flexible use as interlocking or guard locking By means of the corresponding evaluation of the safe device data by the control system, use can be as either interlocking or guard locking (with or without monitoring). Escape releaseThe escape release enables people accidentally shut in to open the guard locked door from the danger zone. Dimension drawing MGB: The MGB-System in use MGB: MGB Impact test MGB: Mounting left door, with escape release Mounting left door, without escape release Mounting right door, without escape release MGB: Deactivating guard lock monitor MGB: Activating guard lock monitor MGB: Activating release monitoring MGB: Change color-lens push button Dimension drawing Technical data Escape release MGB-E-A2-106051 (Order no. 106051) Mechanical values and environment
Housing material | Die-cast zinc/stainless steel powder-coated |
Weight | |
Net | 1,05 kg |
Ambient temperature | -20 ... 55 °C |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Other
Additional feature | With mounting plate |
Product version number | V2.0.0 |
Handle module MGB-H-AA1A6-R-111838 (Order no. 111838) Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,00 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Installation orientation | Door hinge DIN right |
Other
Additional feature | With mounting plate and automatic lockout mechanism |
Product version number | V3.0.0 |
Locking module MGB-L2CB-PN-R-106053 (Order no. 106053) Mechanical values and environment
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 4,05 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Mechanical life | 1 x 106 |
In case of use as door stop, and 1 Joule impact energy | 0,1 x 106 |
Installation orientation | Door hinge DIN right |
Reaction time | |
Enabling switch | max.250 ms Switch-off time |
Operating mode selector switch | max.220 ms Switch-off time |
Emergency stop / machine stop | max.250 ms Switch-off time |
Door position | max.550 ms Switch-off time |
Bolt position | max.550 ms Switch-off time |
Guard locking | max.550 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | |
| Push-pull power |
| Push-pull power |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
| Push-pull RJ45 |
| Plug connector RC12 |
Guard locking principle | Open-circuit current principle |
Locking force FZh | 2000 N |
Electrical connection ratings
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Transponder coding | Multicode |
| Power supply X1 |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Fusing | |
external | min.1 A Slow blow |
| Power supply X2 |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Work area
Assured switch-off distance Sar | max.65 mm |
Interface, bus
Data interface | |
Data protocol | |
Bus protocol | Profinet (IEC 61158 type 10) |
Safety protocol | Profisafe (IEC 61784-3-3) |
Other
Product version number | V3.30.10 |
Slide-in label | |
| S-Zone Secured |
| Line Stop |
| Cooling Water Extraction On |
| Cooling Water Extraction Off |
| Safety Gate Open |
| S-Zone Reset |
| Anlage Start |
| Anlage Stopp |
| Cooling water on |
| Cooling water off |
| Open safety door |
| S-Bereich Quittieren |
| S-Bereich Gesichert |
| Line Start |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
Category | 4 |
Performance Level | PL e |
PFHD | 4.07 x 10-8 |
Diagnostic Coverage (DC) | 99 |
| Emergency stop |
B10D | |
Emergency stop | 0.1 x 106 |
| Emergency-stop evaluation |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
| Selector switch evaluation |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
| Enabling switch |
B10D | |
Enabling switch | According to manufacturer’s specifications |
| Enabling switch evaluation |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Mission time | 20 |
Components 106051 Escape release MGB-E-A2-106051
- Escape release out of the danger area
- Mounted on mounting plate
- With red handle
- 118 mm long
111838 Handle module MGB-H-AA1A6-R-111838
- Intelligent bolt tongue
- Fold-out lockout mechanism
- Second automatically extending lockout mechanism
- Door handle
- Mounting plate
106053 Locking module MGB-L2CB-PN-R-106053
- Guard locking with guard lock monitoring
- Emergency stop according to ISO 13850
- 8 pushbuttons illuminated
- Operating mode selector switch
- 1 indicator
- Including adhesive labels
- Push-pull plug
- Including terminal plug for enabling switch (RC12, 12-pin)
- Pre-assembled on mounting plates
- Integrated Profinet RT switch
- Multicode