Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 100753 CMS-R-BZB-SC

Euchner CMS-R-BZB-SC 100753

 CMS-R-BZB-SC Euchner 100753
Manufacturer
Euchner
Name
CMS-R-BZB-SC
Part number
100753
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 100753 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 100753 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 100753 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 100753 spares for all applications.

  • Swift Delivery: Quick access to Euchner 100753 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 100753 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 100753 Industrial components.

Order Euchner 100753 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CMS-R-BZB-SC 100753

  • In combination with evaluation units ESM-BA...
  • Cube-shaped version 36 x 26 mm
  • Plug connector M8
Alignment of read head and actuator Operating diagrams, design B for ESM CMS-R-BZB
  • Typ. switch-on distance
  • Typ. switch-off distance
Design B
Housing material Fiber glass reinforced PPS
Weight
Net 0,016 kg
Ambient temperature -20 ... 60 °C
Degree of protection IP67
Mechanical life 100 x 106
Installation orientation Any, pay attention to marking
Tightening torque 0,4 ... 0,5 Nm
Number of NO contacts 2 NO contacts with fuse, 100 mA each
Connection 4-pin M8 plug connector
Method of operation Magnetic, reed contact
Electrical connection ratings
Rated conditional short-circuit current 100 A
Fusing
Power supply / safety contacts, external contact protection Fuse 10 A gG
Switching voltage 24 ... 35 V DC
Switching current max.100 mA
Switching characteristics Parallel
Switching voltage according to UL
According to UL Class 2 max.24 V AC/DC
Switching frequency, electrical
At I_min = 10 mA max.5 Hz
At nominal current 8 A max.0,1 Hz
Switching delay from state change 26 ms
Other
In compliance with EN ISO 13849-1: 2015, EN 62061: 2005 + AC: 2010 + A1: 2013 + A2: 2015, EN ISO 14119: 2013, IEC 60947-5-3: 2013
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
B10D 20 x 106
In combination with Evaluation unit ESM-BA201, ESM-BA202, ESM-BA203, ESM-BA301, ESM-BA302, ESM-BA303, ESM-BA201P, ESM-BA301P and Actuator CMS-M-BHOperating distance
Center offset
At s=3 mm read distance 2,5 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao
With center offset m=0 min.7 mm