Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 099258 CMS-E-FR

Euchner CMS-E-FR 099258

 CMS-E-FR Euchner 099258
Manufacturer
Euchner
Name
CMS-E-FR
Part number
099258
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 099258 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 099258 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 099258 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 099258 spares for all applications.

  • Swift Delivery: Quick access to Euchner 099258 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 099258 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 099258 Industrial components.

Order Euchner 099258 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CMS-E-FR 099258

  • Up to 30 read heads can be connected
  • 2 safety contacts
  • 1 auxiliary contact
  • 6 door monitoring outputs
  • 1 feedback loop can be connected
  • Start automatic/monitored/not monitored
Functional The evaluation unit CMS-E-FR is suitable for the direct connection of up to 30 read heads. Category/PL according to EN ISO 13849-1
  • Category 3/PL d with more than one read head connected
  • Category 4/PL e with only one read head connected
Notice:At low approach speeds in the z direction, the time between the switching of the reed contacts must not be more than 0.6 ms. Dimension drawing Wiring diagram CMS: Magnetically coded safety switches Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material Polyamide PA6.6
Weight
Net 0,3 kg
Ambient temperature 0 ... 55 °C
Degree of protection Terminals IP20 / housing IP40
Mechanical life 10 x 106
Mounting method Mounting rail 35mm according to DIN EN 60715 TH35
Connection Connection terminals
Safety contacts 13/14, 23/24
Number of safety contacts 2
Auxiliary contacts 31/32
Number of auxiliary contacts 1
Semiconductor outputs 01 to 06
Number of monitoring outputs 6
Electrical connection ratings
Operating voltage
AC/DC 24 V -10% ... +10%
Fusing
Protection internal (operating voltage UB) 0,75 A Automatically resetting fuse PTC
Rated insulation voltage Ui
AC 250 V
Degree of contamination (external, according to EN 60947-1) 2
Connection cross-section 0,14 ... 2,5 mm?
LED indicator 1 indicator LED Power, 2 output LEDs and 6 status indicators for the read heads
Safety contacts 13/14, 23/24
Type of output Relay contacts, floating
Switching voltage
AC max.240 V
Switching current
at DC 24V 10 ... 3000 mA
Fusing
External contact fuse (safety circuit) acc. to EN IEC 60269-1 4A gG
Utilization category according to EN 60947-4-1
Utilization category according to EN 60947-5-1
AC-15 0.9A , 240V and 0.9A , 24V
DC-13 1.5A , 24V
Switching load
According to UL class 2 Input: 24V AC/DC , output: 30V AC, 24V DC
Breaking capacity (VA) max.720 VA
Risk time according to EN 60947-5-3 20 ms
Auxiliary contacts 31/32
Type of output Relay contacts, floating
Switching current
at DC 24V max.1500 mA
Semiconductor outputs 01 to 06
Type of output Semiconductor outputs, p-switching
Switching current
at DC 24V 50 mA Per monitoring output 01 to 06
Other
In compliance with EN ISO 13849-1: 2015, EN ISO 13849-2:2012, EN 50178: 1997, EN 60204-1: 2006/A1: 2009, EN ISO 13850: 2015, EN 14119: 2013, EN 6100-2-6: 2005, EN 6100-6-3: 2007/A1: 2011, EN 60947-5-3: 2013
Reliability values according to EN ISO 13849-1
Monitoring of the safety guard position
Category
With more than one read head 3
With one read head 4
Performance Level
With one read head PL e
With more than one read head PL d
PFHD
With one read head 2.5 x 10-8
With more than one read head 1.0 x 10-7
Number of switching cycles
? 0.1A at 24V DC max.166000 1/Jahr
? 1A at 24V DC max.70000 1/Jahr
Mission time 20 y
In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-05V, CMS-R-AXH-SC and Actuator CMS-M-ACOperating distance
Center offset
At s =3 mm read distance 2,5 mm
Assured switch-off distance Sar max.31 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-RH-BYB-03VL, CMS-RH-BYB-05VL and Actuator CMS-MH-BBOperating distance
Center offset
At s =3 mm read distance 2,5 mm
Assured switch-off distance Sar max.13 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EFOperating distance
Center offset
At s =3 mm read distance 2,5 mm
Assured switch-off distance Sar max.17 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-RH-AYA-03VL, CMS-RH-AYA-05VL and Actuator CMS-MH-AAOperating distance
Center offset
At s =3 mm read distance 2,5 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao
With center offset m=0 min.10 mm
In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CAOperating distance
Center offset
At s =3 mm read distance 2,5 mm
Assured switch-off distance Sar max.14 mm
Assured operating distance Sao
With center offset m=0 min.6 mm
In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-07P, CMS-R-BXI-SC and Actuator CMS-M-BDOperating distance
Center offset
At s =3 mm read distance 2,5 mm
Assured switch-off distance Sar max.12 mm
Assured operating distance Sao
With center offset m=0 min.3 mm