Supply of spare parts for industrial enterprises around the world
Home Brands Euchner 095793 CEM-A-LH10R-S3

Euchner CEM-A-LH10R-S3 095793

 CEM-A-LH10R-S3 Euchner 095793
Manufacturer
Euchner
Name
CEM-A-LH10R-S3
Part number
095793
Country
Germany
Sale of any product from the Euchner catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Euchner (official website: www.euchner.de/en-us/). We sell only certified goods and give an official guarantee from the manufacturer Euchner


Order Euchner 095793 Spare Parts Online for Enhanced Efficiency

For industries seeking reliable components, Euchner 095793 Industrial parts are the ideal choice. Built with precision and innovation, these Euchner 095793 spare parts optimize industrial operations across USA.

What Makes 2technologie Stand Out?

  • Comprehensive Options: A full range of Euchner 095793 spares for all applications.

  • Swift Delivery: Quick access to Euchner 095793 spare parts near me or online.

  • Cost-Effective Solutions: Quality Euchner 095793 Industrial products at the best prices.

  • Proven Expertise: A trusted provider of Euchner 095793 Industrial components.

Order Euchner 095793 spare parts today and experience the 2technologie difference!

Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications CEM-A-LH10R-S3 095793

  • Read head with guard locking without guard lock monitoring
  • Locking force 1000 N
  • Without remanence
  • Up to category 4 according to EN ISO 13849-1
Without remanenceRead heads without remanence are de-magnetized when the solenoid is switched off. For this purpose the operating voltage UB must always be applied. Approach direction Typical operating distance Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off. Dimension drawing
Material
Solenoid Steel, nickel-plated
Housing material Die-cast aluminum
Read head material Plastic (PPS)
Weight
Net 0,9 kg
Ambient temperature -25 ... 50 °C
Degree of protection IP67
Mechanical life
In case of use as door stop, and 1 Joule impact energy 1 x 106
Installation orientation Any
Switching frequency
Read head See operating instructions for the related evaluation unit
Solenoid max.2 Hz
Connection
X3, read head Plug connector M8x1, 3-pin male (with snap-action / screw terminal)
X2, external LED Plug connector M8x1, 4-pin female (with screw terminal)
X1, solenoid (yellow LED integrated in the plug) Plug connector M8x1, 4-pin male (with snap-action / screw terminal)
Cable length max.25 m
Guard locking principle Open-circuit current principle
Locking force F
(Not monitored, in axial direction) at UCM?24V 1000 N
Adhesive force
due to remanence 0,7 N
Electrical connection ratings
Operating voltage DC
UB 24 V DC -15% ... 10%
UCM 24 V DC -15% ... 10%
Current consumption
On UB at UCM?0V 12 mA
On UB at UCM?24V 225 mA
On UCM at 24V 15 mA
Power consumption 5,8 W
Solenoid duty cycle 100 %
Work area
Switching hysteresis 0,7 mm
Assured switch-off distance Sar max.20 mm
Assured operating distance Sao min.2 mm
Center offset -2,5 ... +2,5 mm