- Auxiliary shutdown feature on the front
- With door unlock request contact
- Increased horizontal overtravel
Approach direction Horizontal and vertical Can be adjusted in 90° steps Increased overtravel for horizontal approach direction Solenoid operating voltage
LED function display (optional)A function display (2 LEDs, red and green) is available for the following voltage ranges:
Guard locking types
TP5 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
TP6 | Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force. |
Switching elements
4120 | Slow-action switching contact 1 NC (door unlock request contact) + 1 NC + 1 NO (solenoid monitoring contact) |
Auxiliary shutdown featureWhen actuated, positively driven NC contacts 21-22 are opened. The safety guard remains locked. The auxiliary shutdown feature must be sealed to prevent tampering (for example with sealing lacquer). Door unlock request contactWhen the actuator is in the locked state positively driven NC contact 21-22 is opened by pulling the safety guard (6 mm actuator stroke) as a result of which a signal is forwarded to the controlling PLC. Depending on the control concept, the safety guard can be unlocked automatically - when machine components which were still running have stopped.
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65 |
Mechanical life | 0,5 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 2 |
Number of NO contacts | 1 |
Connection | |
1 x | Plug connector SR11 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Locking force Fmax | 800 N |
Locking force FZh | 600 N |
Retention force | 10 N |
Extraction force | 20 N |
Actuating force | 10 N |
Electrical connection ratings
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 50V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
B10D | 3 x 106 |
| Control of the guard locking |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
Overtravel A B C D E | 2 mm |
Overtravel K L M N | 1,5 mm |
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
Overtravel A B C D E | 7 mm |