- Auxiliary release on the front
- Increased horizontal overtravel
- Optional without guard lock monitoring
Guard locking types
TP3 | Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0. |
TP4 | Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force. |
Control of the guard locking solenoidThe guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition the 24V connection can be switched safely. AS-Interface inputs, version AS1
D0, D1 | Door monitoring contact SK |
D2, D3 | Solenoid monitoring contact UK |
AS-Interface inputs, version AS1
D0, D1 | Door monitoring contact SK 1 |
D2, D3 | Door monitoring contact SK 2 |
Evaluation is performed via a safety monitor. AS-Interface outputs
D0 | Guard locking solenoid |
D1 | Red LED |
D2 | Green LED |
LED function display
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | |
According to As-i Safety at work | 2 D0,D1,D2,D3 |
Connection | |
1 x | Plug connector M12 (4-pin) |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Open-circuit current principle |
Retention force | 10 N |
Extraction force | 20 N |
Actuating force | 10 N |
Electrical connection ratings
ASi voltage | 30 V 22,5 ... 31,6 V |
ASi operating current | max.45 mA |
ASi auxiliary voltage | |
IEC 60742, PELV | 24 V -15% ... +10% |
ASi auxiliary current | 300 mA |
Solenoid duty cycle | 100 % |
ASi slave type | |
According to ASI specification 2.1 | EA code: 7 |
| ID code: B |
ASi data in | |
According to ASI safety at work | D0,D1,D2,D3 |
ASi data out | |
Guard locking solenoid | D0 |
LED red | D1 |
LED green | D2 |
ASi LED | |
LED green | Power |
LED red | Fault |
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
Overtravel | |
Horizontal | 2 mm |
Vertical | 1,5 mm |
Insertion depth | |
Horizontal | 28 mm |
Vertical | 29,5 mm |
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
Overtravel | |
Horizontal | 7 mm |
Insertion depth | |
Horizontal | 28 mm |