- With exterior diaphragm
- plunger spacing 12 mm
- Upright housing, small flange
- Degree of protection IP67 according to IEC 60529
Exterior diaphragmThe exterior diaphragm protects the plunger guide against the entry of very fine dust (dust from grinding, casting, glass, etc.) and prevents the plunger seizing. At the same time, plunger sticking, caused by resinous lubricating coolants, can be prevented with this exterior diaphragm version. Switching elements
ES 502 E | Snap-action switching contact 1 NC + 1 NO |
ES 508 | Slow-action switching contact 1 NC |
On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN ISO 14119, i.e. riveted, welded or secured in some other way against becoming loose. LED function display (on request)LED function display possible on request.
Contact bounce time | < 3ms |
Contact closing time | |
Switching element ES502E | < 4ms |
Design | Upright |
Housing material | Die-cast aluminum, anodized |
Weight | |
Net | 0,4 kg |
Ambient temperature | -5 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 30 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | |
Switching element ES508 | Slow-action switching contact |
Switching element ES502E | Snap-action switching contact |
Plunger spacing | 12 mm |
Installation orientation | Any |
Number of switching elements | 2 |
Number of positively driven contacts | 1 |
Number of NC contacts | 1 |
Number of NO contacts | 1 |
Connection | 2 x M20 x 1.5 |
Approach speed | 0,01 ... 20 m/min |
Actuating element | Chisel plunger |
Actuating force | min.20 N |
Operating point accuracy | ± 0.002 |
Electrical connection ratings
Thermal rated current Ith | 8 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 6A 230V |
DC-13 | 6A 24V |
AC-12 | 8 A, 250 V |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 8A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching current | |
Min. at DC 24V switching element ES508 | min.10 mA |
Min. at DC 12V switching element ES502E | min.10 mA |
Connection cross-section | 0,34 ... 1,5 mm? |
Other
Additional information | |
| Exterior diaphragm = AM |
| Mixed contact assembly |
Reliability values according to EN ISO 13849-1