- Four read heads can be connected
- 1 safety contact
- 1 auxiliary contact
- 1 feedback loop can be connected
Functional The evaluation unit CMS-E-BR is suitable for the direct connection of up to 4 read heads. Category/PL according to EN ISO 13849-1
- Category 3/PL d with more than one read head connected
- Category 4/PL e with only one read head connected
Notice:At low approach speeds in the z direction, the time offset when switching the reed contacts must not be more than 150 ms. Dimension drawing Wiring diagram CMS: Magnetically coded safety switches Dimension drawingWiring diagram Technical dataApprovals Mechanical values and environment
Housing material | Polycarbonate (PC) |
Weight | |
Net | 0,24 kg |
Ambient temperature | 0 ... 50 °C |
Degree of protection | Terminals IP20 / housing IP40 |
Mechanical life | 30 x 106 |
Mounting method | Mounting rail 35mm according to DIN EN 60715 TH35 |
Number of read heads | Up to 4 read heads |
Connection | Connection terminals, plug-in |
| Safety contacts 13/14 |
Number of safety contacts | 1 |
| Auxiliary contacts 23/24 |
Number of auxiliary contacts | 1 |
Electrical connection ratings
Operating voltage | |
AC/DC | 24 V -10% ... +10% |
Fusing | |
Protection internal (operating voltage UB) | 0,5 A Automatically resetting fuse PTC |
Rated insulation voltage Ui | |
AC | 250 V |
Degree of contamination (external, according to EN 60947-1) | 2 |
Connection cross-section | 0,14 ... 2,5 mm? |
LED indicator | 1 indicator LED Power (UB) green 1 LED safety output (OUT green/red) 8 LED status indicators (Dx1 / Dx2 /green/ red) |
| Safety contacts 13/14 |
Type of output | Relay contacts, floating |
Current consumption | 250 mA |
Switching voltage | |
AC | max.250 V |
Switching current | |
at DC 24V | 13 ... 3000 mA |
Fusing | |
External contact fuse (safety circuit) acc. to EN IEC 60269-1 | 3A gG |
Utilization category according to EN 60947-4-1 | |
Utilization category according to EN 60947-5-1 | |
AC-15 | 1A , 250V , 1A 24V |
DC-13 | 3A , 24V |
Switching load | |
Switching load acc. to UL Class 2 | Input: 24V AC/DC : Output: 30V AC , 24V DC |
Breaking capacity (VA) | max.750 VA |
Risk time according to EN 60947-5-3 | 20 ms |
| Auxiliary contacts 23/24 |
Type of output | Relay contact, floating |
Other
In compliance with | EN ISO 13849-1: 2015, EN 50178: 1997, EN ISO 14119: 2013, EN 6100-6-3: 2007, EN 60947-5-2: 2007/A1: 2012, EN 60947-5-3: 2013 |
Reliability values according to EN ISO 13849-1
| Monitoring of the safety guard position |
Category | |
With one read head | 4 |
With more than one read head | 3 |
Performance Level | |
With one read head | PL e |
With more than one read head | PL d |
PFHD | |
With one read head | 2.5 x 10-8 |
With more than one read head | 1.0 x 10-7 |
Number of switching cycles | |
? 0.1A at 24V DC | max.100000 1/Jahr |
? 1A at 24V DC | max.18500 1/Jahr |
? 3A at 24V DC | max.9000 1/Jahr |
Mission time | 20 y |
In combination with Read head CMS-R-AXH-03V, CMS-R-AXH-SC and Actuator CMS-M-ACOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.31 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-R-BXI-03V, CMS-R-BXI-05V, CMS-R-BXI-SC, CMS-R-BXI-07P and Actuator CMS-M-BDOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.12 mm |
Assured operating distance Sao | |
With center offset m=0 | min.3 mm |
In combination with Read head CMS-R-CXC-03V, CMS-R-CXC-05V, CMS-R-CXC-05P, CMS-R-CXC-SC and Actuator CMS-M-CAOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.14 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |
In combination with Read head CMS-R-EXM-03V, CMS-R-EXM-05V, CMS-R-EXM-SC and Actuator CMS-M-EFOperating distance
Center offset | |
At s=3 mm read distance | 2,5 mm |
Assured switch-off distance Sar | max.17 mm |
Assured operating distance Sao | |
With center offset m=0 | min.6 mm |