Specifications TP4-2131A024M 084145

  • Auxiliary release on the front
  • With door monitoring contact
  • Increased horizontal overtravel
Approach direction Horizontal and vertical Can be adjusted in 90° steps Increased overtravel for horizontal approach direction Solenoid operating voltage
  • AC/DC 24 V +10%, -15%
Guard locking type
TP4Open-circuit current principle, guard locking by applying voltage to the guard locking solenoid. Release by spring force.
Switching element
2131Slow-action switching contact 2 NC + 1 NO + 1 NC (door monitoring contact)
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Housing material Reinforced thermoplastic
Weight
Net 0,5 kg
Ambient temperature -20 ... 55 °C
Degree of protection IP67
Mechanical life 1 x 106
Contact material Silver alloy, gold flashed
Switching principle Slow-action switching contact
Installation orientation Any
Number of door position positively driven contacts 2
Number of NC contacts 1
Number of NO contacts 1
Connection
3 x M20 x 1.5
Approach speed
max. 20 m/min
Actuation frequency 1200 1/h
Guard locking principle Open-circuit current principle
Locking force Fmax 1300 N
Locking force FZh 1000 N
Retention force 10 N
Extraction force 20 N
Actuating force 10 N
Electrical connection ratings
Thermal rated current Ith 4 A
Utilization category according to EN 60947-5-1
AC-15 4A 230V
DC-13 4A 24V
Solenoid operating voltage
AC/DC 24 V -15% ... +10%
Short circuit protection according to IEC 60269-1
(Fuse) 4A gG
Rated insulation voltage Ui 250 V
Rated impulse withstand voltage Uimp 2,5 kV
Switching voltage
Min. at 10mA 12 V
Switching current
Min. at 24V 1 mA
Power consumption 8 W
Solenoid duty cycle 100 %
Connection cross-section 0,34 ... 1,5 mm?
Reliability values according to EN ISO 13849-1
Monitoring of guard locking and the safety guard position
B10D 3 x 106
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
Overtravel A B C D E 2 mm
Overtravel K L M N 1,5 mm
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
Overtravel A B C D E 7 mm