- Auxiliary release on the front
- Two LED indicators, red and green
- Plug connector SR6
- Actuating head fitted right
Approach direction Horizontal Can be adjusted in 90° steps Solenoid operating voltage and LED function display
Guard locking type
TZ2 | Open-circuit current principle, guard locking by applying voltage to the solenoid. Release by spring force. |
Switching element
SK | For monitoring the door/actuator position |
UK | For monitoring the guard locking (built-in solenoid) |
528H | Slow-action switching contact 1 NC + 1 NO |
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. Sealing can be fitted to protect against tampering. Lead seal kit and tool included (already pre-assembled on versions with plug connectors).
Housing material | Anodized die-cast alloy |
Weight | |
Net | 1,2 kg |
Ambient temperature | -25 ... 80 °C |
Degree of protection | IP65 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 1 |
Number of door position NO contacts | 1 |
Number of guard lock monitoring positively driven contacts | 1 |
Number of guard lock monitoring NO contacts | 1 |
Connection | |
1 x | Plug connector SR6 |
Approach speed | max.20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 2000 N |
Locking force FZh | 1500 N |
Retention force | 10 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.52 mm |
Cover lid | Black |
Electrical connection ratings
Thermal rated current Ith | 4 A 70°C => 2A'> |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V 70°C => 2A'> |
DC-13 | 4A 24V 70°C => 2A'> |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG 70°C => 2A gG'> |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 10 W |
Solenoid duty cycle | 100 % |
LED indicator | Operating voltage corresponds to the solenoid voltage |
Other
C number | |
C1638 | Special wiring |
Reliability values according to EN ISO 13849-1
| Monitoring of guard locking and the safety guard position |
B10D | 3 x 106 |
In combination with Actuator BETAETIGER-Z-GNMechanical values and environment
In combination with Actuator BETAETIGER-Z-GMechanical values and environment