Supply of spare parts for industrial enterprises around the world

Emirel RV5

Voltage relay RV5 Emirel
Manufacturer
Emirel
Name
RV5
Country
Italy
Type
Voltage relay
Sale of any product from the Emirel catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Emirel (official website: www.emirelsrl.it). We sell only certified goods and give an official guarantee from the manufacturer Emirel


FUNCTION The device controls a direct voltage at the input, by two set points: one max set point and the second can be set as min or max set point. USE The device controls the direct voltage at the input.
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications RV5

REGULATIONS AND GENERAL FEATURES (fig. 4,5) SP1 Max set point, adjustable by means of screwdriver. The scale is divided in 10 parts. The value of each part corresponds to 1/10 of the full scale FS. SP2 Set point adjustable by screwdriver as max or min power set point. The scale is divided in 10 parts. The value of each part corresponds to 1/10 of the full scale FS. When the SLIDER m/M-DS2 is “UP” (Fig. 1) the SP2 is MAX set point. When the SLIDER is “DOWN” the SP2 is min. set point (in that case, with the slider A/Ⱥ the condition V=0 is selected as “ALARM” (UP POSITION) or “NO ALARM” (DOWN POSITION), fig. 5/1 and 5/2). The minimum value which can be set is 1/10 of the full scale. TC Initial timer adjustable by screwdriver on the front (0,1÷10 sec) excluding set point triggerings at the start, for covering an eventual initial spike. It covers both the sets points. The timer is activated when the voltage overcomes the internal set point Vm (Vm corresponds to 1/10 of the range. Ex.: VFS=100V, Vm=10V). T1 Timer delaying the internal relay associated to the set point SP1 (0,1÷10 sec). T2 Timer like T1 for the set point SP2. VISUALIZATIONS ON GREEN LED supply on A1 RED LED set point SP1 alarm A2 RED LED set point SP2 alarm In case of one SET POINT overcoming, during T1, T2, TC, the led A1 (and/or A2) flashes quickly, at the end of T1 (or T2) the led A1 (and/or A2) remainslighted, with FIXED LIGHT, if the overcoming continues to be present. The led A1 (or A2) flashes at LOW FREQUENCY, if the memory started and the overcoming stopped. MODE OF OPERATION When the voltage is applied at the input, the timer TC bypasses the eventual spike. After the end of TC, each set point triggers after the delay time T1 and T2. INPUTS Voltage pins: 19-17. Input Resistance = 10 kW/V. OUTPUT RELAY 5A(NO) 3A(NC)-230 Vac resistive load R1 9-10 NO 9-8 NC Device not supplied R2 5-6 NO or in alarm 5-4 NC SUPPLY: (single voltage) 2VA 50-60 Hz - tolerance ±10% 13-12: 24Vac or 48Vac or 115Vac or 230 Vac CASE 70x75x110 mm for DIN rail. WORKING TEMPERATURE: 0÷70°C WEIGHT: Kg 0,300 COLOUR: grey, similar to RAL 35.