Manufacturer
Bosch Rexroth
Part number
0811404608
Country
Germany
Type
Directional valve
Sale of any product from the Bosch Rexroth catalog at competitive prices
2technologie will help you choose and buy products and spare parts from Bosch Rexroth (official website: ). We sell only certified goods and give an official guarantee from the manufacturer Bosch Rexroth
General information
The high-response valve type 4WRPEH is a direct operated directional control valve with electric position feedback and integrated electronics (OBE). In the integrated electronics (OBE), the specified command value is compared with the position actual value. In case of control deviations, the stroke solenoid will be activated which - due to the changed magnetic force - adjusts the control spool against the spring. Stroke/control cross-section is controlled proportionally to the command value. In case of a command value presetting of 0 V, the electronics adjusts the control spool against the spring to central position. In deactivated condition, the spring is untensioned to a maximum and the valve is in fail-safe position.
Switch-off behavior
With switched-off electronics, the valve will immediately move into the relevant secured basic position (fail-safe). In this connection, it moves through the switching position P–B/A–T which may result in movements at the controlled component. This has to be considered in the system design.
Valves type 4WRPEH are direct operated directional control valve with electrical position feedback and integrated electronics (OBE). Set-up The 4WRPEH high-response valve mainly consists of:
1 | Control solenoid with position transducer |
2 | Valve body |
3 | Connector for possible 2nd stage |
4 | Mating connector |
Valves type 4WRPEH are direct operated directional control valve with electrical position feedback and integrated electronics (OBE). Set-up The 4WRPEH high-response valve mainly consists of:
- Valve housing with control spool and sleeve in servo quality (1)
- Control solenoid with position transducer (2) (optional with electronics protection membrane (5))
- On-board electronics (OBE) (3) with analog or IO-Link interface (4) (optionally with damping plate (6))
- Falling below the minimum supply voltage
- Only at interface "F1":
- Falling below the minimum current command value of 2 mA (includes cable break of the command value line (current loop))
- Only at interface "L1":
- Enable inactive, communication interruption (watchdog)
- In case of internal IO-Link error
- Only at interface "C6":
- Additionally release inactive