Supply of spare parts for industrial enterprises around the world
Home Brands Bosch Rexroth R901086489 4WRGE 10 V50L-1X/210G15ETK31/A1M

Bosch Rexroth 4WRGE 10 V50L-1X/210G15ETK31/A1M R901086489

Proportional pressure reducing valve 4WRGE 10 V50L-1X/210G15ETK31/A1M Bosch Rexroth R901086489
Manufacturer
Bosch Rexroth
Name
4WRGE 10 V50L-1X/210G15ETK31/A1M
Part number
R901086489
Country
Germany
Type
Proportional pressure reducing valve
Sale of any product from the Bosch Rexroth catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Bosch Rexroth (official website: ). We sell only certified goods and give an official guarantee from the manufacturer Bosch Rexroth


The 4/3 directional high-response valve is designed for subplate mounting, with position control and integrated control electronics. It controls the flow proportionally to the input signal, continuously from P to B and A to T or also from P to A and B to T. Set-up: The valve consists of four main assemblies:
  • low-friction pilot control valve (1) with dry 2-gap torque motor; valve housing (2) with orifices (3) and filter (4)
  • Housing of the main stage (5) with spring-centered control spool (6)
  • Control electronics (7) with amplifier to control the pilot control valve (1) and for the position control of the main control spool (6)
  • inductive position transducer (8) for position sensing of the main control spool (6)
Functional description:
  • Control of the pilot control valve by means of a command value from 0 to ±10 V or from 0 to ± 10 mA
  • Comparison command/actual value in the control electronics → In case of control deviation, the torque motor will be activated and the flapper plate will be deflected according to the control amplitude.
  • Detuning of the control pressures using the control and fixed orifices → Deflection of the main control spool (6)
  • Achievement of the position of the main control spool according to the command value presetting → Control deviation has been reduced to almost 0 V → Control process is completed
  • Pilot oil supply to the pilot control valve internally via port P or externally via port X Pilot oil drain internally via port T or externally via Y to the tank
Notice: In case of supply voltage failure, however with available operating pressure, the main control spool (6) will take an undefined position. The acceleration forces occurring in this connection may cause machine damage. If a directional sandwich plate valve is used, the two control lines in the main stage will be short-circuited in case of power failure. With control spool form E, E1- and Q2-, the centering spring (9, 10) bring the main control spool (6) in central position, V- and V1 control spools are switched to preferred direction P to B and A to T in a tolerance range of 1% to a maximum of 11% of the control spool stroke. In case of operating pressure failure and if no directional sandwich plate valve is used, you will observe the same behavior. Type 4WRGE…-1X/… Pilot oil supply external; pilot oil drain external In this version, the pilot oil is supplied from a separate control circuit (externally). The pilot oil drain is not directed into the T channel of the main valve, but is separately directed to the tank via port Y (externally). Type 4WRGE…-1X/…E… Pilot oil supply internal, pilot oil drain external In this version, the pilot oil is supplied from the P channel of the main valve (internally). The pilot oil drain is not directed into the T channel of the main valve, but is separately directed to the tank via port Y (externally). In the subplate, port X is to be closed. Type 4WRGE…-1X/…ET… Pilot oil supply internal, pilot oil drain internal In this version, the pilot oil is supplied from the P channel of the main valve (internally). The pilot oil is directly drained to channel T of the main valve (internally). In the subplate, ports X and Y are to be closed. Type 4WRGE…-1X/…T… Pilot oil supply external; pilot oil drain internal In this version, the pilot oil is supplied from a separate control circuit (externally). The pilot oil is directly drained to channel T of the main valve (internally). In the subplate, port Y is to be closed. Position 1 and 2: Plug screw M6 DIN 906-8.8 SW 3
Pilot oil supply Section a - a External Internal 1 1 closed open
Pilot oil return Section b - b External Internal 2 2 closed open
Pilot oil supply Section a - a External Internal P P closed open
Pilot oil return Section b - b External Internal 1 1 closed open
Pilot oil supply Section a - a External Internal 1 1 closed open
Pilot oil return Section b - b External Internal 2 2 closed open
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications 4WRGE 10 V50L-1X/210G15ETK31/A1M R901086489

  • Size 10 … 25
  • Component series 1X
  • Maximum operating pressure 350 bar
  • Maximum flow 870 l/min
  • Nominal flow 50 … 350 l/min