Manufacturer
Bosch Rexroth
Part number
R901359935
Country
Germany
Type
Directional valve
Sale of any product from the Bosch Rexroth catalog at competitive prices
2technologie will help you choose and buy products and spare parts from Bosch Rexroth (official website: ). We sell only certified goods and give an official guarantee from the manufacturer Bosch Rexroth
General information
The pilot-operated IFB Multi-Ethernet valve (Integrated Fieldbbus) is a digital directional control valve with integrated fieldbus:
Function (symbol V, V1- and Q3-)
When the control solenoid of the pilot control valve is de-energized, its spring-operated control spool is in the "fail safe" position. The control spool of the main valve is in the spring-centered offset position at approx. 6% of the stroke in direction P→B/A→T.
The integrated electronics (OBE) compare the specified command value to the position actual value of the control spool of the main stage. In case of a control deviation, the control solenoid of the pilot control valve is activated and its control spool is adjusted.
The flow which is activated via the control cross-sections at the pilot control valve leads to an adjustment of the control spool of the main valve. The stroke/control cross-section of the main valve is regulated proportionally to the command value. In case of a command value presetting of 0%, the electronics adjust the control spool of the main valve to central position.
The pilot oil supply in the pilot control valve is either internal via port P or external via port X. The feedback can be internal via port T or external via port Y to the tank.
Switching off the release (symbol V and V1-)
The control spool of the main valve is not in a safe position after the release is switched off. The enable acknowledgement is not set (pin C). If the supply voltage fails or in case of cable break, the integrated electronics will de-energize the control solenoid, the pilot control spool will move to the fail-safe position and will unload the pilot oil chambers of the main valve. Operated by the spring, the control spool of the main valve will move to the offset position (approx. 6% P→B/A→T).
Function (symbol E. and W.)
When the control solenoid of the pilot control valve is de-energized, its spring-operated control spool is in the "fail safe" position. The control spool of the main valve is in spring-centered central position.
The integrated electronics (OBE) compare the specified command value to the position actual value of the control spool of the main stage. In case of a control deviation, the control solenoid of the pilot control valve is activated and its control spool is adjusted.
The flow which is activated via the control cross-sections at the pilot control valve leads to an adjustment of the control spool of the main valve. The stroke/control cross-section of the main valve is regulated proportionally to the command value.
The pilot oil supply in the pilot control valve is either internal via port P or external via port X. The feedback can be internal via port T or external via port Y to the tank.
Switching off the release (symbol E., W. and Q3-)
If the control spool of the main valve is in the safe position, the enable acknowledgement is set (pin C).
If the control spool of the main valve leaves the safe position or the release is set, the enable acknowledgement expires. If the supply voltage fails or in case of cable break, the integrated electronics will de-energize the control solenoid, the pilot control spool will move to the fail-safe position and will unload the pilot oil chambers of the main valve. Operated by the spring, the control spool
of the main valve will move to the central position.
Monitoring
The digital control electronics enable comprehensive monitoring functions/error detection including:
Version “XY"
External pilot oil supply, external pilot oil return
In this version, the pilot oil is supplied from a separate control circuit (external). The pilot oil return is not directed into channel T of the main valve, but is separately directed to the tank via port Y (external).
Version “PY”
Internal pilot oil supply, external pilot oil return
With this version, the pilot oil is supplied from channel P of the main valve (internally). The pilot oil return is not directed into channel T of the main valve, but is separately directed to the tank via port Y (external). In the subplate, port X is to be closed.
Version “PT”
Internal pilot oil supply; internal pilot oil return
With this version, the pilot oil is supplied from channel P of the main valve (internally). The pilot oil is directly returned to channel T of the main valve (internally). In the subplate, ports X and Y are to be closed.
Version “XT”
External pilot oil supply, internal pilot oil return
In this version, the pilot oil is supplied from a separate control circuit (external). The pilot oil is directly returned to channel T of the main valve (internally). In the subplate, port Y is to be closed.
- The following operating modes are possible:
- Standard:
- Valve direct control
- Flow control
- Version "5" (with external pressure sensors):
- Pressure/force control
- Active damping
- Substitutional control (flow - pressure/force); pQ function (flow-controlled)
- Command value presetting is done via the Ethernet interface (X7E1 or X7E2)
- The feedback information of the actual value signals to the superior control system is provided via the Ethernet interface (X7E1 or X7E2)
- The controller parameters are set via the Ethernet interface (X7E1 or X7E2)
- Pilot control valve (1) with control spool and sleeve in servo quality
- Main stage (2) with centering springs and position feedback
- Integrated fieldbus (3) with:
- connector, voltage supply, safety shut-down (XH1)
- Ethernet interfaces (X7E1, X7E2)
- analog sensor interfaces (X2N)
- interface for the position transducer of the main stage (X8A)
1) | Only version "5" |
- Undervoltage
- Communication error
- Cable break for analog sensor inputs
- Monitoring of the microcontroller (watchdog)
- Temperature of the integrated electronics
- Project planning
- Parameterization
- Commissioning
- Diagnosis
- Comfortable administration of all data on a PC
- PC operating systems: Windows 7-10
- Symbol V and V1-:
- Pilot-operated 4/3 directional control valves are only functional in the active control loop and do not have a locking basic position when deactivated. Consequently "external isolator valves" are required in many applications and must be taken into account regarding the switch-on/switch-off order.
- While the electrical supply voltage is being switched off, the drive may be accelerated for a short time in functional direction P → B.
- Symbol E. and W.:
- Pilot-operated 4/3 directional control valves with positive overlap are functional in controlled or regulated axes. The overlap in the de-energized state is approx. 20% of the control spool stroke.
- While the release is being switched off, the drive may be accelerated for a short time in functional direction P → B (see operating instructions 29391-B).
Pilot oil supply | |
External Internal | 2, 3 closed 2, 3 open |
Pilot oil return | |
External Internal | 1 closed 1 open |
1 | Plug screw M6 according to DIN 906, wrench size 3 - Pilot oil return |
2 | Plug screw M6 according to DIN 906, wrench size 3 - Pilot oil supply |
3 | Plug screw M12x1.5 according to DIN 906, SW6 - Pilot oil supply |
6 | Housing cover main stage (position transducer side) |