Supply of spare parts for industrial enterprises around the world

Bosch Rexroth R901080966

Valve amplifier  Bosch Rexroth R901080966
Manufacturer
Bosch Rexroth
Part number
R901080966
Country
Germany
Type
Valve amplifier
Sale of any product from the Bosch Rexroth catalog at competitive prices

2technologie will help you choose and buy products and spare parts from Bosch Rexroth (official website: ). We sell only certified goods and give an official guarantee from the manufacturer Bosch Rexroth


General information The amplifier modules are snapped onto top hat rails according to EN 60715. The electrical connection is established via screw terminals. The modules are operated at 24 V direct voltage. Power supply unit [1] The amplifier modules have a power supply unit with making current limiter. This unit supplies all internally required positive and negative supply voltages. The making current limiter prevents high making current peaks. Command value presetting The internal command value signal is calculated from the total [3] of the external command value signal available at the differential input [2] and the zero point offset (zero point potentiometer "Zw"). A positive command value results in a current increase in the solenoid and thus a pressure increase in the valve. Enable function [11] The enable function enables the current output stages and forwards the internal command value signal to the ramp generator. The enable signal is indicated by an LED on the front plate. If enable is connected, the internal command value is changed (with any kind of command value presetting) by the set ramp time. Thus, a controlled valve does not open abruptly. Ramp generator [4] The ramp generator limits the incline of the control output. The amplitude attenuator does not extend or shorten the ramp time. Information on ramp time settings and measurement:
Value at measuring socket "t " U/V 5 3 2 1 0.5 0.3 0.2 0.1 0.05 0.03 0.02
Current ramp time (±20 %) t/ms 20 33 50 100 200 333 500 1000 2000 3333 5000
Formula for calculation of the ramp times: t in ms, U in volt at the measuring socket Amplitude attenuator [5] By means of the amplitude attenuator "Gw", the maximum value can be adjusted to the hydraulic requirements in a range between 0 and 100 %. Amplitude limiter [6] The internal command value is limited to 0 % and 110 %. Oscillator [9] The oscillator creates the control signal for the inductive position transducer. Demodulator [10] The demodulator supplies the actual value signal of the control spool position from the position transducer signal. +100 % ≙ +10 V at measuring socket "x" Controller for the control spool position [7] The position controller is intended to minimize the valve hysteresis and is optimized in a valve-specific manner. Current output stage [8] The current output stage creates the clocked solenoid current for the proportional valve. The solenoid current is limited to approx. 1.85 A. The output stage output is short-circuit-proof. The output stage is de-energized in case of an internal fault signal or if the enable signal is missing. Fault recognition [14] The position transducer cable is monitored for cable break and short-circuits on the primary side as well as for over-currents at the output stage. [ ] = Assignment to the block diagram
Worldwide delivery services
Worldwide delivery services
Ways of payment
Ways of payment

Specifications R901080966

  • Component series 1X
  • Analog, Modular design
  • For valves: 2FRE10-4X, 2FRE16-4X