Manufacturer
AirCom Pneumatic
Part number
VGM-C1_01
Country
Germany
Weight (g)
500
Sale of any product from the AirCom Pneumatic catalog at competitive prices
2technologie will help you choose and buy products and spare parts from AirCom Pneumatic (official website: www.aircom.net). We sell only certified goods and give an official guarantee from the manufacturer AirCom Pneumatic
Thermal mass flow meter based on high precision MEMS technology
(CMOS sensor). Pressure and temperature insensitive
according to the CTA constant temperature principle. Also insensitive
to pressure surges.
Media: compressed air or non-corrosive gases
Operating_pressure: max. 10 bar
Supply_voltage: Standard AA battery or Micro-USB power supply
(DIN62684), optionally external power +12 ...+30 V DC (max. 200 mA)
Display: Touch-display 128 x 64 px, blacklighted only with external
power supply (Micro-USB or 24 V DC)
Electrical_connector: optionally length 2.0 m, with free ends at 24 V DC
Function: totalisator included, physical units can be changed
Alarm_functions: 3 configurable alarms,
programmable as = low alarm, high alarm, window alarm and totalizer alarm.
The alarms can be configured with different parameters as delay and alarm duration.
Relais: switching current up to 1A, switching voltage 30 V DC
Accuracy: ± 2% FS, from 200 l/min ± 3% FS
Response_time: 500 ms at 99% accuracy
Turndown_ratio: 1 to 50 (Eco) or 1 to 1000 (Special)
Protection_class: IP 50
Flow_regulation: manual fine adjustment by 15 turns
Mounting position: any, horizontal from 5 bar on
Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
Warm-up_time: < 1 sec. for full accuracy
Body: aluminium, optionally electropolished stainless steel 316
Elastomer: FKM, optionally EPDM
(CMOS sensor). Pressure and temperature insensitive
according to the CTA constant temperature principle. Also insensitive
to pressure surges.
Media: compressed air or non-corrosive gases
Operating_pressure: max. 10 bar
Supply_voltage: Standard AA battery or Micro-USB power supply
(DIN62684), optionally external power +12 ...+30 V DC (max. 200 mA)
Display: Touch-display 128 x 64 px, blacklighted only with external
power supply (Micro-USB or 24 V DC)
Electrical_connector: optionally length 2.0 m, with free ends at 24 V DC
Function: totalisator included, physical units can be changed
Alarm_functions: 3 configurable alarms,
programmable as = low alarm, high alarm, window alarm and totalizer alarm.
The alarms can be configured with different parameters as delay and alarm duration.
Relais: switching current up to 1A, switching voltage 30 V DC
Accuracy: ± 2% FS, from 200 l/min ± 3% FS
Response_time: 500 ms at 99% accuracy
Turndown_ratio: 1 to 50 (Eco) or 1 to 1000 (Special)
Protection_class: IP 50
Flow_regulation: manual fine adjustment by 15 turns
Mounting position: any, horizontal from 5 bar on
Temperature_range: 0 °C to 50 °C / 32 °F to 122 °F
Warm-up_time: < 1 sec. for full accuracy
Body: aluminium, optionally electropolished stainless steel 316
Elastomer: FKM, optionally EPDM