Manufacturer
AirCom Pneumatic
Part number
RLM-08J1
Country
Germany
Weight (g)
7500
Sale of any product from the AirCom Pneumatic catalog at competitive prices
2technologie will help you choose and buy products and spare parts from AirCom Pneumatic (official website: www.aircom.net). We sell only certified goods and give an official guarantee from the manufacturer AirCom Pneumatic
The pilot pressure regulator/booster regulates the outlet
pressure through a signal pressure at ratio of 1 to 1.
Functioning as a pressure regulator the pilot pressure may
either be internally inducted from the inlet pressure or
externally. The dome chamber is closed by a needle valve.
Functioning as a volume booster the dome is controlled by
a proportional pressure regulator or a pilot pressure regulator.
Media: compressed air, non-corrosive gases or liquids
Supply_pressure:
max. 25 bar for RL.-0.J1,
max. 100 bar for RL.-0.J2,
max. 40 bar for oxygen,
max. 1.5 bar for acetylene
Pilot_pressure:
max. 24 bar for RL.-0.J1,
max. 99 bar for RL.-0.J2
Pilot_port: G1/4
Accuracy:
at supply pressure variation of 10 bar = 0.1 bar pressure deviation
at temperature variation of 3 °C / K = 1% pressure deviation at internal pilot pressure
Air_consumption: without constant bleed
Relieving_function: non-relieving
Gauge_port: not available
Mounting_position: any, dome preferably mounted up
Temperature_range:
-20 °C to 100 °C / -4 °F to 212 °F for FKM,
-40 °C to 130 °C / -4 °F to 266 °F for EPDM
Body: brass or stainless steel 1.4571
Inner_valve: brass or stainless steel 1.4571
Elastomer: FKM, optionally EPDM
pressure through a signal pressure at ratio of 1 to 1.
Functioning as a pressure regulator the pilot pressure may
either be internally inducted from the inlet pressure or
externally. The dome chamber is closed by a needle valve.
Functioning as a volume booster the dome is controlled by
a proportional pressure regulator or a pilot pressure regulator.
Media: compressed air, non-corrosive gases or liquids
Supply_pressure:
max. 25 bar for RL.-0.J1,
max. 100 bar for RL.-0.J2,
max. 40 bar for oxygen,
max. 1.5 bar for acetylene
Pilot_pressure:
max. 24 bar for RL.-0.J1,
max. 99 bar for RL.-0.J2
Pilot_port: G1/4
Accuracy:
at supply pressure variation of 10 bar = 0.1 bar pressure deviation
at temperature variation of 3 °C / K = 1% pressure deviation at internal pilot pressure
Air_consumption: without constant bleed
Relieving_function: non-relieving
Gauge_port: not available
Mounting_position: any, dome preferably mounted up
Temperature_range:
-20 °C to 100 °C / -4 °F to 212 °F for FKM,
-40 °C to 130 °C / -4 °F to 266 °F for EPDM
Body: brass or stainless steel 1.4571
Inner_valve: brass or stainless steel 1.4571
Elastomer: FKM, optionally EPDM