Manufacturer
AirCom Pneumatic
Part number
PM1DE-C1
Country
Germany
Weight (g)
500
Sale of any product from the AirCom Pneumatic catalog at competitive prices
2technologie will help you choose and buy products and spare parts from AirCom Pneumatic (official website: www.aircom.net). We sell only certified goods and give an official guarantee from the manufacturer AirCom Pneumatic
Proportional control valves with closed loop control
technology for better control of pressurised gases.
The instruments can be built as single closed loop or
dual closed loop control valves.
Media: dry, lubricated or unlubricated and 5 µm filtered
compressed air or non-corrosive gases
Fail_freeze: constant outlet pressure at voltage drop
Second_loop: 0...10 V, impedance 4.7 kΩ, ratio of internal to external relationship is 10% to 90%
Supply_voltage: 15...24 V DC, residual ripple < 10%, with reverse voltage protection
Command signal: 0-10V, 4-20mA as an option
Impedance:
0...10 V / 4.7 kΩ,
4...20 mA / 100 Ω,
jumper selectable command
Monitor_signal: 0...10 V at max. 10 mA
Electrical_ports: terminal strip for 2.5 mm2
Power_consumption: 3.6 W regulating, 0.5 W non-regulating
Air_consumption: without constant bleed
Linearity/Hysteresis: < 0.15% FS
Repeatability: < 0.02 FS
Temperature_influence: < 1% FS at 0 °C to 50 °C / 32 °F to 122 °F
Adjustment: zero point and span
Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F
Mounting_position: any, vibration-resistant
Ports: brass
Elastomer: FKM
Transducer: aluminium and silicon
Valves: nickel-plated brass
technology for better control of pressurised gases.
The instruments can be built as single closed loop or
dual closed loop control valves.
Media: dry, lubricated or unlubricated and 5 µm filtered
compressed air or non-corrosive gases
Fail_freeze: constant outlet pressure at voltage drop
Second_loop: 0...10 V, impedance 4.7 kΩ, ratio of internal to external relationship is 10% to 90%
Supply_voltage: 15...24 V DC, residual ripple < 10%, with reverse voltage protection
Command signal: 0-10V, 4-20mA as an option
Impedance:
0...10 V / 4.7 kΩ,
4...20 mA / 100 Ω,
jumper selectable command
Monitor_signal: 0...10 V at max. 10 mA
Electrical_ports: terminal strip for 2.5 mm2
Power_consumption: 3.6 W regulating, 0.5 W non-regulating
Air_consumption: without constant bleed
Linearity/Hysteresis: < 0.15% FS
Repeatability: < 0.02 FS
Temperature_influence: < 1% FS at 0 °C to 50 °C / 32 °F to 122 °F
Adjustment: zero point and span
Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F
Mounting_position: any, vibration-resistant
Ports: brass
Elastomer: FKM
Transducer: aluminium and silicon
Valves: nickel-plated brass