Manufacturer
AirCom Pneumatic
Part number
DAA-C2H_01
Country
Germany
Weight (g)
180
Sale of any product from the AirCom Pneumatic catalog at competitive prices
2technologie will help you choose and buy products and spare parts from AirCom Pneumatic (official website: www.aircom.net). We sell only certified goods and give an official guarantee from the manufacturer AirCom Pneumatic
Pressure transducer in compact and robust stainless steel
housing with piezo-resistive measuring element.
Factory-made calibration of zero point and range is possible.
Media: compressed air, non-corrosive gases or liquids
Overpressure:
max. 3x full scale, min. 3 bar,
for DAA-D6 and DAA-E1 max. 1500 bar
Supply_voltage:
9...33 V DC at current signal,
15...30 V DC at voltage signal,
residual ripple 5%, reverse voltage protection,
short-circuit-proof
Ex_Atex_version:
only current signal 10...30 V DC, max. 1 W,
as per EN 50.014 / EN 50.020 - 1974 A1…A5, Atex 2640-1
Electrical_connector: plug according to DIN 43650,
with coupling socket
Output_signal:
4...20 mA = max. power consumption 260 mW
0...10 V = max. power consumption 50 mW
Linearity/Hysteresis: < 0.5 FS
Repeatability: < 0.1 FS
Long-term_stability: < 0.2 FS, < 0.9 FS at version up to 500 mbar
Temperature_sensitivity:
< 0.02% FS per °C / K,
< 0.06% FS at version up to 2 bar per °C / K,
< 0.1% FS at version up to 500 mbar per °C / K,
at range of 0 °C to 70 °C / 32 °F to 158 °F
Response_time: 1 ms for 10...90% of pressure range
Shock_resistance: 50 g
Vibration_resistance: 10 g at 5...500 Hz
Protection_class: IP 65
Mounting_position: any
Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F
Body/Diaphragm: stainless steel 316L, mat. no. 1.4435
O-rings: FKM, optionally EPDM
housing with piezo-resistive measuring element.
Factory-made calibration of zero point and range is possible.
Media: compressed air, non-corrosive gases or liquids
Overpressure:
max. 3x full scale, min. 3 bar,
for DAA-D6 and DAA-E1 max. 1500 bar
Supply_voltage:
9...33 V DC at current signal,
15...30 V DC at voltage signal,
residual ripple 5%, reverse voltage protection,
short-circuit-proof
Ex_Atex_version:
only current signal 10...30 V DC, max. 1 W,
as per EN 50.014 / EN 50.020 - 1974 A1…A5, Atex 2640-1
Electrical_connector: plug according to DIN 43650,
with coupling socket
Output_signal:
4...20 mA = max. power consumption 260 mW
0...10 V = max. power consumption 50 mW
Linearity/Hysteresis: < 0.5 FS
Repeatability: < 0.1 FS
Long-term_stability: < 0.2 FS, < 0.9 FS at version up to 500 mbar
Temperature_sensitivity:
< 0.02% FS per °C / K,
< 0.06% FS at version up to 2 bar per °C / K,
< 0.1% FS at version up to 500 mbar per °C / K,
at range of 0 °C to 70 °C / 32 °F to 158 °F
Response_time: 1 ms for 10...90% of pressure range
Shock_resistance: 50 g
Vibration_resistance: 10 g at 5...500 Hz
Protection_class: IP 65
Mounting_position: any
Temperature_range: 0 °C to 70 °C / 32 °F to 158 °F
Body/Diaphragm: stainless steel 316L, mat. no. 1.4435
O-rings: FKM, optionally EPDM